STARTECH ADJDINKIT 2U Adjustable DIN Rail Kit 19in server accessory
- Rail Kit
- U Height: 2U Frame…
GIGABYTE
A 2U rackmount barebones system holding four dual-socket nodes with 24 hot-swap 2.5″ Gen5 NVMe/SATA/SAS-4 bays
The GIGABYTE H274-S60-AAW1 is a 2U rackmount barebones system housing four independent dual-processor nodes. Each node supports Intel Xeon 6 processors in LGA 4710 sockets with TDPs up to 225W. It targets AI, ML and HPC workloads requiring maximum compute density in a compact chassis.
All four nodes and 24 hot-swap drive bays are accessed from the rear, simplifying service in dense racks. No CPUs or memory are installed; each node requires two Xeon 6 processors and up to 16 DDR5 RDIMM or MCR DIMM modules across eight channels. Incorrect DIMM population or missing CPU power cables are the most common setup errors.
Confirm your rack accommodates a 2U rear-service chassis with sufficient airflow for four dual-socket nodes. Ensure the PDU can deliver enough current for up to eight 225W processors plus memory and drives. Check that 1GbE via four Intel I350-AM2 ports per system meets management needs and plan for any OCP 3.0 or PCIe Gen5 add-in cards required.
| Brand | GIGABYTE |
|---|---|
| Model | H274-S60-AAW1 |
| Form Factor | 2U Rackmount |
| Workload | AI/ML/HPC |
| CPU Type | Intel Xeon 6 Processors - Intel Xeon 6700-Series Processors - Intel Xeon 6500-Series Processors |
| CPU Socket | LGA 4710 |
| Installed CPU | No CPU Installed |
| Max Processors | 8 |
| CPU Features | Dual processor per node, TDP up to 225W |
| Memory Slots | 64 x 288Pin |
| Installed Memory Size | No Memory Installed |
| Memory Type Supported | RDIMM: Up to 6400 MT/s MRDIMM: Up to 8000 MT/s |
| Channel Supported | 8 Channel |
| Registered | Yes |
| Installed HDD | No Storage Installed |
| GPU/VPU | Aspeed AST2600 |
| PCI Express | 8 x LP PCIe Gen5 x16 slots 4 x OCP NIC 3.0 PCIe Gen5 x16 slots |
| First LAN | 4 x Intel I350-AM2 |
| Max. LAN Speed | 1 Gigabit |
| Hot-Swap Bays | 24 x 2.5" Gen5 NVMe/SATA/SAS-4 - (NVMe & SATA from CPU_1) |
| Buttons | 4 x Reset buttons 1 x CMC reset button |
| LEDs | 4 x Power buttons with LED 4 x ID buttons with LED 4 x System status LEDs 1 x CMC status LED |
| DisplayPort | 4 x Mini DisplayPorts |
| Rear USB | 8 x USB 3.2 Gen1 ports (Type-A) |
| RJ45 | 8 |
| Other Ports | 4 x MLAN |
| Max. Power | Dual 3000W 80 PLUS Titanium redundant power supply |
| Fans | 4 x 80x80x80mm (16,500rpm) |
| Temperature | Operating temperature: 10°C to 35°C Non-operating temperature: -40°C to 60°C |
| Humidity | Operating humidity: 8-80% (non-condensing) Non-operating humidity: 20%-95% (non-condensing) |
| Dimensions | 2U 4-Node - Rear access 3.44" x 17.32" x 34.53" |
| Package Contents | 1 x H274-S60-AAW1 8 x CPU heatsinks 1 x Mini-DP to D-Sub cable 16 x Carriers 1 x 3-Section Rail kit |
| 배송 무게 | 30.00 kg |
| 포장 크기 | 1179 × 700 × 380 mm |
The Aspeed AST2600 BMC provides out-of-band management; use its web interface or IPMI to confirm all four nodes report healthy POST, sensor readings and drive presence across the 24 hot-swap bays.
The barebones chassis includes the 2U enclosure, four node boards with LGA 4710 sockets, 64 DDR5 slots, 24 Gen5 NVMe/SATA/SAS-4 bays, eight LP PCIe Gen5 x16 slots, four OCP NIC 3.0 slots and four Intel I350-AM2 1 Gb/s LAN ports; CPUs, RDIMM or MRDIMM memory and storage drives are not installed.
Select MRDIMM at 8000 MT/s for maximum throughput on memory-bound AI/ML/HPC workloads; choose RDIMM at 6400 MT/s when capacity per module or cost per gigabyte is the priority.
이 진열대의 다른 상품
같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.
결제할 코인과 가격을 확인할 통화입니다.
체크아웃 시 지갑에서 전송됩니다.
표시 전용 — 카탈로그 가격은 달러 기준입니다.
일치하는 통화가 없습니다.
사이트에서 사용할 언어를 선택하십시오.
일치하는 언어가 없습니다.
처음 방문하셨나요?
이미 계정이 있으신가요?
자동 재설정 기능은 없습니다. 이 쇼핑몰은 어떠한 메일도 보내지 않으므로 요청할 일회용 링크 자체가 없습니다. 계정에 등록된 이메일 주소를 그대로 두시면 담당자가 직접 확인해 처리합니다.
요청 접수
받은편지함으로 오는 것은 아무것도 없습니다 — 이 쇼핑몰은 메일을 전혀 보내지 않습니다. 담당자가 직접 확인해 처리합니다.
기억나셨나요?