We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC AP6003A Basic PDU 20A 14 C13

SKU CH-1PMP-A3FSD MPN AP6003A

Distributes 100-240 VAC power through 14 C13 outlets from a single C20 inlet with 16 A overload protection

  • TypeBasic
  • CertificationsUL / C-UL, VDE, CE
  • ROHS2011/65/EU - latest revision
  • Input Voltage100 - 240 VAC +/- 10%
  • Input Frequency50/60 Hz
  • Maximum Input Current20A
  • Distributes power to 14 C13 outlets from a single C20 inlet
  • Supports 100-240 VAC input for worldwide rack compatibility
  • 20 A maximum input current with 16 A overload protection
  • Half-height 1.85" profile fits dense rack environments
  • Certified to UL, VDE, CE and RoHS 2011/65/EU standards

Rack power distribution for dense server rows

This APC basic PDU delivers 14 IEC C13 outlets from a single C20 inlet, accepting 100 to 240 VAC at 50 or 60 Hz. It suits server rooms and network cabinets that need reliable outlet multiplication without metering or switching features. Installers working within standard rack depths will find the half-height form factor straightforward to mount. Buyers who need individual outlet control or remote power monitoring should consider a managed unit instead.

Steady 16 A branch protection across all outlets

The unit carries a 16 A overload breaker that protects the entire strip rather than each socket independently. Maximum input current is rated at 20 A, though regulatory derating limits continuous draw to 12 A in many regions. This arrangement handles sustained loads from multiple servers or switches without nuisance tripping, provided the aggregate stays within the derated figure. Builders planning to run every outlet at high simultaneous draw must verify their local code allowance.

Passive cooling in 0 to 50 °C environments

No fans are fitted, so the PDU adds no acoustic noise to the rack and draws no power for its own operation. It operates reliably up to 50 °C and 95 % relative humidity at elevations up to 10 000 feet. The metal enclosure dissipates heat from the breaker and bus bars through convection alone. Cabinets with restricted airflow should confirm that ambient temperatures remain within the specified range.

Highlights

  • Distributes power to 14 C13 outlets from a single C20 inlet
  • Supports 100-240 VAC input for worldwide rack compatibility
  • 20 A maximum input current with 16 A overload protection
  • Half-height 1.85" profile fits dense rack environments
  • Certified to UL, VDE, CE and RoHS 2011/65/EU standards

Specifications

BrandSchneider Electric
ModelAP6003A
TypeBasic
CertificationsUL / C-UL, VDE, CE
ROHS2011/65/EU - latest revision
Input Voltage100 - 240 VAC +/- 10%
Input Frequency50/60 Hz
Maximum Input Current20A
Regulatory Derated Input Current12A
Input Connector(s)IEC-320 C20 inlet
Output Voltage100 - 240 VAC +/- 10%
Output Connector(s)14 x C13
Overload Protection16A
Operating Environment0 - 50 Celcius degree
Operating Relative Humidity5 - 95%
Operating Elevation0 - 10000 Feet
Storage Temperature-15 - 60 Celcius degree
Storage Relative Humidity5 - 95%
Storage Elevation0 - 50000 Feet
Dimensions1.85" x 4.84" x 24.10"
Weight3.08 lbs.
Shipping weight1.80 kg
Package size610 × 127 × 127 mm