We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC BE600M1 Back-UPS 600VA UPS 120V 7 Outlets USB Charging

SKU CH-3KRB-33RKD MPN BE600M1

Battery-backup UPS with 600 VA, 330 W, seven outlets and one USB charging port, 11.75 minutes at half load

  • International Version120V
  • Input Voltage Range92 - 139V
  • Input Frequency50/60 Hz +/- 3 Hz (auto sensing)
  • Input ConnectionNEMA 5-15P
  • VA Rating600 VA
  • Watts330 Watts

VA 600 VA

  • 600 VA / 330 W capacity keeps essential devices running during outages
  • 5 battery-backup outlets + 2 surge-only outlets protect computers and peripherals
  • USB smart charging port powers phones or tablets without a separate adapter
  • 75 minutes at half load / 3.2 minutes at full load gives time for safe shutdown
  • Automatic self-test and wiring-fault indicator warn of battery or circuit problems early

Compact desktop UPS for home electronics

The APC BE600M1 is a 600 VA battery backup that delivers 330 watts of output power from a 120 V supply. It provides seven NEMA 5-15R outlets, five of which are backed by the internal lead-acid battery while the remaining two offer surge-only protection. A single USB charging port allows convenient power for phones or tablets. The tower form factor sits on a desk or shelf and includes a building-wiring fault indicator and audible alarms for status changes.

Suitable for routers, modems and light desktop loads

This unit suits users who need brief ride-through for networking gear, a monitor and a modest PC during short outages. The half-load run time of 11.75 minutes and full-load run time of 3.2 minutes cover typical brown-outs and allow an orderly shutdown. Buyers who need more storage capacity for extended runtime or who require rack-mount installation should consider a larger or rack-compatible model.

Behaviour under sustained load

At full rated load the battery supports the output for 3.2 minutes before depletion, after which a 10-hour recharge restores full capacity. The automatic self-test runs periodically to detect aging cells early, while the overload alarm sounds a continuous tone if demand exceeds 330 watts. Input voltage is accepted between 92 and 139 V with auto-sensing 50/60 Hz frequency, so the UPS remains online through common line fluctuations without draining the battery.

Highlights

  • 600 VA / 330 W capacity keeps essential devices running during outages
  • 5 battery-backup outlets + 2 surge-only outlets protect computers and peripherals
  • USB smart charging port powers phones or tablets without a separate adapter
  • 75 minutes at half load / 3.2 minutes at full load gives time for safe shutdown
  • Automatic self-test and wiring-fault indicator warn of battery or circuit problems early

Specifications

BrandAPC
SeriesBack-UPS
ModelBE600M1
International Version120V
Input Voltage Range92 - 139V
Input Frequency50/60 Hz +/- 3 Hz (auto sensing)
Input ConnectionNEMA 5-15P
VA Rating600 VA
Watts330 Watts
Output Voltage120V
Output Frequency50/60Hz +/- 3 Hz
Outlets7
Outlet Type5 x NEMA 5-15R (Battery Backup)
2 x NEMA 5-15R (selector-surgetitle)
Battery TypeLead Acid Battery
Battery Run TimeRun Time at Half load: 11.75 minutes
Run Time at Full load: 3.2 minutes
Battery Recharge Time10 Hours
AlarmsAlarm when on battery: distinctive low battery alarm: overload continuous tone alarm
Interface PortUSB
ApprovalsCalifornia (CEC) Battery Charger, cTUVus, NOM
RackmountableNot rack-mountable
Surge Energy Rating490 Joules
TemperatureOperation Temperature: 32 - 104°F (0 - 40°C)
Storage Temperature: 5 - 113°F (-15 - 45°C)
HumidityRelative Humidity: 0 - 90 % non-condensing
Storage Relative Humidity: 0 - 95 % non-condensing
FeaturesAdjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications
Audible alarms: Provides notification of changing utility power and UPS power conditions
Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced
Battery failure notification: Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Building Wiring Fault Indicator: This LED informs users of potentially dangerous wiring problems in the wall circuit
Co
Dimensions5.47" x 10.79" x 4.13"
Weight7.69 lbs.
Shipping weight3.88 kg
Package size363 × 193 × 168 mm

Other versions of this model

4 more in the same range

Same family, different memory, cooler or clock — compare before you commit.

Questions about this item

What type of wall plug do I need for the NEMA 5-15P input connection?

The unit uses a standard NEMA 5-15P plug, so a regular 120 V grounded wall outlet is required.

Will my existing NEMA 5-15R power cords fit the seven outlets on this unit?

Yes, all seven outlets are NEMA 5-15R receptacles, so standard North American power cords will connect directly.

How can I confirm the UPS is protecting my equipment after I plug it in?

The LED display shows unit and utility power status, while audible alarms signal battery, low-battery and overload conditions.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.