We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

APC

APC Smart-UPS On-Line SRT10KRMXLT 10000 VA UPS

SKU CH-S5YG-VPEW1 MPN SRT10KRMXLT

Double-conversion on-line UPS delivering 10 kW at 208 V with seven outlets and network management card included

  • Input Voltage Range160 - 275V
  • Input Frequency45 - 65 Hz (auto sensing)
  • Input ConnectionHard Wire 3-wire (2PH + G)
  • VA Rating10000 VA
  • Watts10 kW
  • Output Voltage208V
  • 10 kW continuous power protects critical loads
  • True double-conversion topology ensures clean 208 V output
  • Seven mixed NEMA L6-20R and L6-30R outlets plus hard-wire input
  • Network Management Card plus USB, serial and Smart-Slot enable remote monitoring
  • Battery recharges in 3 hours using APCRBC140 modules

Capacity and form factor

The APC Smart-UPS On-Line SRT10KRMXLT delivers 10000 VA and 10 kW of double-conversion on-line power protection in a 6U rackmountable chassis. It is built for servers, voice and data networks, medical labs and light industrial sites that need continuous, regulated output voltage.

Thermals noise and power draw

The unit operates from an input range of 160 to 275 V at 45 to 65 Hz with power factor correction and internal bypass. Audible and visible alarms are prioritised by severity, while the management software enables unattended graceful shutdown of connected systems.

Output connections and runtime

Seven outlets comprise one hard-wire 3-wire connection, four NEMA L6-20R and two NEMA L6-30R sockets, all supplying 208 V at 50 or 60 Hz. Battery recharge takes three hours using the APCRBC140 replacement pack, and matching battery packs can be added when runtime in hours is required.

Highlights

  • 10 kW continuous power protects critical loads
  • True double-conversion topology ensures clean 208 V output
  • Seven mixed NEMA L6-20R and L6-30R outlets plus hard-wire input
  • Network Management Card plus USB, serial and Smart-Slot enable remote monitoring
  • Battery recharges in 3 hours using APCRBC140 modules

Specifications

BrandAPC
SeriesSmart-UPS On-Line
ModelSRT10KRMXLT
Input Voltage Range160 - 275V
Input Frequency45 - 65 Hz (auto sensing)
Input ConnectionHard Wire 3-wire (2PH + G)
VA Rating10000 VA
Watts10 kW
Output Voltage208V
Output Frequency50/60Hz +/- 3 Hz
Outlets7
Outlet Type(1) Hard Wire 3-wire (2PH + G)
(4) NEMA L6-20R
(2) NEMA L6-30R
Battery Recharge Time3 hour(s)
Battery ReplaceableAPCRBC140
AlarmsAudible and visible alarms prioritized by severity
Interface PortContact Closure, RJ-45 10/100 Base-T, RJ-45 Serial, Smart-Slot, USB
Management SoftwareYES
ApprovalsENERGY STAR (USA), FCC Part 15 Class A, UL 1778
Rackmountable6U
Surge Energy Rating480 Joules
FeaturesAPC Smart-UPS On-Line,10 kW /10 kVA,Input 208V /Output 208V, Interface Port Contact Closure, RJ-45 10/100 Base-T, RJ-45 Serial, Smart-Slot, USB, Extended runtime model, Rack Height 6 U
Dimensions10.35" x 17.00" x 28.15" (H x W x D)
Weight246.00 lbs.
Package ContentsAPC Smart-UPS SRT10KRMXLT 10000VA RM 208V,CD with software, Documentation CD, Installation guide, Rack Mounting brackets, Rack mounting hardware, Rack Mounting support rails, Temperature Probe, USB cable, Warranty card
Shipping weight132.90 kg
Package size1000 × 600 × 461 mm

Questions about this item

How do I connect the hard-wire 3-wire input and which phase orientation is critical?

The SRT10KRMXLT requires a hard-wire 3-wire (2PH + G) feed at 160-275V; the step often missed is verifying the two-phase rotation matches the unit's expected sequence before tightening the terminals.

Which battery cartridge replaces the internal cells and how often should it be swapped?

Order the APCRBC140 replacement cartridge; plan on swapping it every three to five years depending on temperature and discharge cycles.

At what load does the 480-joule surge rating stop absorbing transients?

The 480-joule rating is a single-event energy limit; once cumulative surge energy exceeds that value the MOVs degrade and further transients pass through to connected equipment.