DELL
DELL PowerEdge R440 1U rack server 2× Xeon Gold 5118 2.3 GHz 12-core 64 GB DDR4 H330 8× 600 GB SAS 2× 550 W
1U rack server with dual 12-core Xeon Gold 5118 CPUs at 2.3 GHz, 64 GB DDR4 ECC, H330 controller, eight 600 GB 10K SAS drives and dual 550 W supplies
- Dual Xeon Gold 5118 CPUs deliver 24 cores at 2.3 GHz base clock
- 64 GB DDR4-2400 ECC memory ensures reliable virtualization performance
- PERC H330 controller manages 8× 600 GB 10K SAS drives
- iDRAC 9 Express provides remote server monitoring and administration
- Redundant 550 W platinum power supplies maintain uptime in 1U rack
Compact 1U Rack Server
The Dell PowerEdge R440 is a 1U rackmount server built for dense data-centre deployments. It targets organisations running virtualisation, cloud, database or application hosting workloads that need reliable compute in minimal rack space.
Dual Xeon Gold 5118 Upgrade
This configuration upgrades from single-socket or lower-core platforms by adding two 12-core Intel Xeon Gold 5118 processors running at 2.3 GHz with 3.2 GHz turbo. The jump is worth it when multi-threaded throughput and memory capacity must scale beyond a single CPU.
Ready Rails Not Included
Installation uses standard 1U rails, but the supplier notes that front bezel and ready rails are not included, so plan for separate rail procurement. The PERC H330 controller manages the eight 600 GB SAS drives, and dual 550 W platinum power supplies provide redundancy.
Highlights
- Dual Xeon Gold 5118 CPUs deliver 24 cores at 2.3 GHz base clock
- 64 GB DDR4-2400 ECC memory ensures reliable virtualization performance
- PERC H330 controller manages 8× 600 GB 10K SAS drives
- iDRAC 9 Express provides remote server monitoring and administration
- Redundant 550 W platinum power supplies maintain uptime in 1U rack
Specifications
No published specifications for this item yet.
Questions about this item
Will the 1U chassis accept standard 2.5" SAS drives in all eight bays?
Yes, the front panel holds eight 2.5" SAS drives and the PERC H330 controller supports 12 Gb/s SAS and SATA devices.
Does the H330 controller need a separate battery or flash module for write caching during RAID setup?
The H330 uses controller-based RAID without a dedicated cache battery or flash backup, so write caching depends on system power only.
When should the 64 GB DDR4-2400 ECC registered modules be replaced or upgraded?
Replace modules only if memory diagnostics report correctable errors or if workload growth requires more than the installed 64 GB capacity.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.



