We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

DELL

DELL PowerEdge R740xd2 2U rack server 2x Xeon 8160 2.1GHz 24C 256GB DDR4 H330 26x 3.5" 2x 1100W PSU

SKU CH-2QND-BJWYW

2U rack server with dual 24-core Xeon 8160 CPUs, 256 GB DDR4, H330 controller and 26 hot-swap 3.5" trays

  • TypeRack
  • Rack Height2U
  • Redundant Hot-swap PowerYes
  • CPU TypeIntel Xeon
  • CPU Speed2.1GHz (3.7GHz Turbo)
  • CPU SocketLGA 3647
  • Dual Xeon Platinum 8160 CPUs provide 24 cores each for heavy compute
  • 256 GB DDR4-2666 ECC registered memory supports data integrity
  • PERC H330 12 Gb/s SAS/SATA controller manages storage arrays
  • 26 front 3.5-inch drive trays enable high-capacity deployments
  • Dual 1100 W platinum power supplies deliver redundant hot-swap power

Storage-dense 2U server

The Dell PowerEdge R740xd2 is a 2U rack server built for workloads that demand high drive-count density in a compact footprint. It ships with two Intel Xeon Platinum 8160 processors, each running at 2.1 GHz with a 3.7 GHz turbo frequency and 24 cores apiece. The system includes 256 GB of DDR4‑2666 ECC registered memory across eight 32 GB modules. A Dell PERC H330 controller manages up to 26 front-accessible 3.5‑inch drive trays, while dual 1100 W platinum power supplies provide redundant hot‑swap power.

Suited for bulk storage, not GPU or compact builds

This platform fits organisations running software‑defined storage, large backup repositories, media archives or big‑data analytics where raw capacity and drive count are the priority. The 26‑bay chassis and dual‑socket compute make it a natural match for scale‑out storage clusters. Buyers who need GPU acceleration, a smaller rack footprint or fewer drive bays should evaluate other platforms.

26 front 3.5-inch drive trays decide fit

The single specification that determines whether this server matches a requirement is the 26‑bay 3.5‑inch front tray count. If the deployment needs that many large‑form‑factor drives in a 2U space, the R740xd2 satisfies it; if the project calls for a different drive form factor, fewer bays or a different height, another chassis is required.

Highlights

  • Dual Xeon Platinum 8160 CPUs provide 24 cores each for heavy compute
  • 256 GB DDR4-2666 ECC registered memory supports data integrity
  • PERC H330 12 Gb/s SAS/SATA controller manages storage arrays
  • 26 front 3.5-inch drive trays enable high-capacity deployments
  • Dual 1100 W platinum power supplies deliver redundant hot-swap power

Specifications

BrandDELL
SeriesPowerEdge
ModelR740xd2
TypeRack
Rack Height2U
Redundant Hot-swap PowerYes
CPU TypeIntel Xeon
CPU Speed2.1GHz (3.7GHz Turbo)
CPU SocketLGA 3647
Number of CPU Cores24 Core-Processors
CPU FeaturesPlatinum 8160
# of Processors Installed2
MAX Processors2
Installed Memory Size256GB
Memory TypeDDR4
Max Memory Capacity1TB
Number of Memory Slots16
Hard Drive (Installed)None
Storage ControllerDell Perc H330 Controller
HDD Interface0
SSD (Installed)No
Raid LevelRAID 0/1/5/10/50
Ethernet Controller1x Integrated Dual Port 1GbE LOM and 1x Dell EMC Broadcom 57414 Dual Port 10/25Gb SFP28 OCP 2.0 Mezzanine Card
Remote ManagementiDRAC9 Enterprise
LAN Ports4 x Ports
Management PortRJ 45
Operating SystemNo
Features0

Questions about this item

How many 3.5-inch drive trays will need replacing if a bay fails?

The chassis includes 26 Dell EMC 14G 3.5-inch drive trays; any single tray can be swapped without removing the server from the rack.

Which component limits sustained throughput first, the controller or the network card?

The PERC H330 storage controller provides 12 Gb/s SAS/SATA links, while the Broadcom 57414 OCP mezzanine delivers dual 10/25 Gb SFP28 ports, so the storage controller is the first bottleneck.

What is the power draw and heat output when both 1100 W PSUs run continuously?

Dual 1100 W platinum-efficiency supplies share the load; each unit draws only what the system needs, reducing waste heat compared with single-supply designs.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.