We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

DELL

DELL PowerEdge T430 5U rack server 2x Xeon E5-2690 v4 2.6GHz 14-core 16GB DDR4 H730P 8x 2.5" trays 2x 750W PSU

SKU CH-4Y54-YK2F7

5U rack server with dual 14-core Xeon E5-2690 v4 CPUs at 2.6 GHz, 16 GB DDR4, H730P RAID controller, eight 2.5-inch drive trays and dual 750 W PSUs

  • TypeRack
  • Rack Height5U
  • Redundant Hot-swap PowerYes
  • CPU TypeIntel Xeon
  • CPU Speed2.6GHz (3.5GHz Turbo)
  • CPU SocketLGA 2011
  • Dual Xeon E5-2690 v4 processors deliver 14 cores each at 2.6 GHz
  • PERC H730P controller supports RAID 0, 1, 5, 6, 10, 50, 60 with 2 GB cache
  • 16 GB DDR4 ECC memory installed, expandable to 384 GB across 12 slots
  • 8 included 2.5" hot-swap drive trays in a 16-bay 5U chassis
  • Redundant 750 W power supplies and iDRAC 8 Express remote management

Dual Xeon E5-2690 v4 server

The Dell PowerEdge T430 is a 5U rack server equipped with two Intel Xeon E5-2690 v4 processors. Each CPU delivers 14 cores running at 2.6 GHz with a 3.5 GHz turbo frequency. The system ships with 16 GB of DDR4 ECC registered memory across twelve DIMM slots, supporting up to 384 GB total. It targets virtualization, database hosting, and business-critical workloads that demand dual-socket compute density.

Redundant 750 W platinum power

Two hot-swap 750 W platinum-efficiency power supplies provide full redundancy for continuous operation. The H730P storage controller with 2 GB cache manages up to sixteen 2.5-inch drive bays, though only eight trays are included. Integrated dual-port Gigabit Ethernet and iDRAC 8 Express remote management handle network and out-of-band administration without additional cards.

Sixteen-bay chassis with expansion room

The 5U form factor houses sixteen 2.5-inch hot-swap bays for SAS or SATA drives, leaving eight bays open for future storage growth. Twelve memory slots remain partially populated, allowing simple capacity upgrades. PCI Express slots accept additional RAID, networking, or acceleration cards. Front bezel and rack rails are not included, so plan for separate mounting hardware if deploying in a standard rack.

Highlights

  • Dual Xeon E5-2690 v4 processors deliver 14 cores each at 2.6 GHz
  • PERC H730P controller supports RAID 0, 1, 5, 6, 10, 50, 60 with 2 GB cache
  • 16 GB DDR4 ECC memory installed, expandable to 384 GB across 12 slots
  • 8 included 2.5" hot-swap drive trays in a 16-bay 5U chassis
  • Redundant 750 W power supplies and iDRAC 8 Express remote management

Specifications

BrandDELL
SeriesPowerEdge
ModelT430
TypeRack
Rack Height5U
Redundant Hot-swap PowerYes
CPU TypeIntel Xeon
CPU Speed2.6GHz (3.5GHz Turbo)
CPU SocketLGA 2011
Number of CPU Cores14 Core-Processors
CPU FeaturesE5-2690 v4
# of Processors Installed2
MAX Processors2
Installed Memory Size16GB
Memory TypeDDR4
Max Memory Capacity384GB
Number of Memory Slots12
Hard Drive (Installed)None
Storage ControllerDell Perc H730P 2GB Controller
SSD (Installed)No
Raid LevelRAID 0/1/5/6/10/50/60
Ethernet ControllerIntegrated Dell 2x1GbE Dual Port Ethernet Adapter
Remote ManagementiDRAC8 Express
LAN Ports2 x Ports
Management PortRJ 45
Operating SystemNo

Questions about this item

How do I install the two Xeon E5-2690 v4 processors in the LGA 2011 sockets, and what step is often missed?

Align the notches, lower each CPU gently, close the load plate, then secure the lever. The step often missed is applying the correct torque to the heat-sink retention screws in a diagonal pattern so pressure stays even across the die.

What maintenance or replacement will the PERC H730P controller need later?

The controller uses a 2GB cache backed by a battery. That battery degrades over time and must be replaced when the controller logs a cache-battery warning, otherwise write-back caching disables and performance drops.

Which limit appears first when all 16 drive bays run sustained write workloads?

The dual 750W platinum supplies cap total output at 750W with one unit failed. Heavy SAS or SSD write streams across many bays can hit that power ceiling before the 12Gb/s SAS bus saturates.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.