We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

ETASIS Electronics

ETASIS Electronics EFRP-603 600W 100-240VAC 2U IPC Redundant server power supply

SKU CH-4PGJ-MTF0A MPN EFRP-603

Delivers 600 W redundant power in a 2U form factor with 100-240 VAC input and 65 % minimum efficiency

  • Delivers 600W for demanding server workloads
  • Accepts 100-240VAC input for global deployment
  • Redundant 2U form factor keeps systems running
  • 65% minimum efficiency at full load reduces waste
  • Power factor 0.95 minimum lowers harmonic distortion

600W 2U Redundant IPC Power Supply

The ETASIS Electronics EFRP-603 delivers 600W output in a 2U redundant form factor designed for industrial IPC server chassis. It accepts 100 to 240 VAC input at 47 to 63 Hz with a maximum input current of 12 to 6A. Minimum efficiency is 65 percent at full load and power factor reaches 0.95 minimum.

Replaces Failed Unit or Adds Redundancy

This unit replaces a failed 2U redundant module to restore N+1 capability or adds a second module where a single unit currently carries the full load. The upgrade is worth it when uptime requirements demand hot-swap replacement without server shutdown. Hold-up time is 17mS minimum and power-good signal ranges from 200 to 500 ms.

Verify Chassis Slot and Signal Compatibility

Confirm the chassis provides a matching 2U redundant bay and that the backplane supplies the required PSON remote on/off TTL signal. Ensure airflow direction suits the 38x38x28 mm cooling fan and that operating temperature stays within 0 to 50ºC with humidity between 20 and 90 percent.

Highlights

  • Delivers 600W for demanding server workloads
  • Accepts 100-240VAC input for global deployment
  • Redundant 2U form factor keeps systems running
  • 65% minimum efficiency at full load reduces waste
  • Power factor 0.95 minimum lowers harmonic distortion

Specifications

No published specifications for this item yet.

Questions about this item

What chassis height does the 2U redundant form factor require?

The unit fits a standard 2U rack space; allow clearance for the 38x38x28 mm cooling fan at the rear.

How do I connect the remote on/off signal correctly?

Apply a TTL-level signal to the PSON pin; the supply will not start until the signal is asserted.

When should the internal fan be replaced?

Plan replacement if airflow drops or bearing noise appears; the 38x38x28 mm fan is the only moving part.

Also in this aisle