We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

MINUTEMAN

MINUTEMAN RPM3016N1LCD-HW PDU 16-Outlet Switched Hardwired 120V 30A 10ft

SKU CH-P4ZZ-6C0QD MPN RPM3016N1LCD-HW

A switched PDU with 16 NEMA 5-15/20R outlets, hardwired 120 V 30 A input, 10 ft cord, LCD readout and IP-addressable remote outlet control

  • TypePower Distribution Units
  • StyleHorizontal Installation, 0U Vertical Installation
  • Certifications62368-1 Certification
  • Input Voltage120V
  • Maximum Input Current30A
  • Input Connector(s)Hardwire
  • Remote reboot of 16 outlets from one IP address
  • Hardwired 30 A input with 10 ft cord for permanent rack install
  • Local LCD shows amps, IP address, temperature and humidity
  • Email or SNMP trap alerts on overload or threshold events
  • 62368-1 certified with input circuit breaker protection

16-Outlet Switched PDU for 120V 30A Racks

The Minuteman RPM3016N1LCD-HW is a rack-mountable power distribution unit with sixteen NEMA 5-15/20R receptacles. It accepts a hardwired 120V 30A input through a 10 ft cord and supports both horizontal and 0U vertical installation. An integrated LCD shows real-time amperage, IP address, temperature and humidity readings.

Suited for Managed Server Rooms Not for Simple

Network administrators who need IP-addressable outlet switching, SNMP monitoring and email alerts will use the built-in web server and centralized software. Buyers who only need basic power distribution without remote management, environmental sensing or per-outlet control should look at simpler units.

Hardwired 30A Input Determines Installation

The unit requires a hardwired 120V 30A supply and delivers up to 30A total across its sixteen outlets, protected by an input circuit breaker. Facilities without dedicated 30A circuits or the ability to terminate hardwired connections cannot deploy this PDU.

Highlights

  • Remote reboot of 16 outlets from one IP address
  • Hardwired 30 A input with 10 ft cord for permanent rack install
  • Local LCD shows amps, IP address, temperature and humidity
  • Email or SNMP trap alerts on overload or threshold events
  • 62368-1 certified with input circuit breaker protection

Specifications

BrandMINUTEMAN
ModelRPM3016N1LCD-HW
TypePower Distribution Units
StyleHorizontal Installation, 0U Vertical Installation
Certifications62368-1 Certification
Input Voltage120V
Maximum Input Current30A
Input Connector(s)Hardwire
Cord Length10 ft
Output Connector(s)Front Panel Receptacles: (16) 5-15/20R
Maximum Output Current30A
Overload ProtectionInput Circuit Breaker Protection
FeaturesIP-addressable Remote Power Manager
Built-in Web Server to support Remote Power Management
Event Notifications via Email or SNMP Traps
Local LCD displays Amps, IP Address, Temperature and/or Humidity
Daily, Weekly, Monthly & Yearly Power Consumption Data
10/100 Base-T Ethernet Port
IPv4, IPv6 Support and SNMP Support (v1,v2c,v3)
Telnet, SSH Encryption Support
Radius Authentication
User Account for Three Different Permissions Management Systems
Alarm Notification via Email, SNMP, Syslog, LED or Audible Alarm
SSL Web Browser for Set Up and Operation
IP Address Filtering
Maximum 5,000 E
Shipping weight6.80 kg
Package size1359 × 221 × 109 mm

Other versions of this model

5 more in the same range

Same family, different memory, cooler or clock — compare before you commit.

Questions about this item

How do I hardwire the 10 ft input cable into a 120 V 30 A branch circuit and where do installers commonly err?

Terminate the three conductors directly to a dedicated 30 A breaker; the common mistake is landing the neutral on the ground bar or using a 20 A breaker instead of the required 30 A.

Which components will need replacement after extended operation?

The input circuit breaker is the only field-replaceable protection device; the LCD module and internal relay board are not user-serviceable.

At what load does the input circuit breaker trip during sustained use?

The breaker opens when total draw exceeds 30 A on the 120 V feed, which is the first hard limit reached under continuous loading.