Aceitamos criptomoeda — para que as moedas que detém possam comprar material informático real.Pague em cripto, gaste-a em material informático real. Envio seguro gratuito para todo o mundo acima de 399 $. Caixas neutras, sem marca, expedidas a partir da Alemanha.Envio seguro gratuito acima de 399 $. A sua taxa fica bloqueada durante 30 minutos assim que abre a finalização da compra.Taxa bloqueada 30 minutos. Cada artigo é selado, o seu número de série é verificado, e está coberto por uma garantia de 24 meses.Selado, garantido 24 meses.

Artigos guardados Iniciar sessão

ALTRONIX

ALTRONIX AL1012ULACM power supply 8 fuse 12VDC 10A

SKU CH-8MGG-YGF7G

Delivers 12VDC at 10A through eight fused outputs in a steel enclosure with cam lock, meeting UL294 and CUL standards

  • TypeOther
  • Delivers 10A at 12VDC for reliable access control
  • Eight individually fused outputs protect each circuit
  • UL294 and CUL listed for safety compliance
  • Steel enclosure with cam lock secures installation
  • 115VAC 60Hz input suits standard mains supply

Power Supply with Eight Fused Outputs

The ALTRONIX AL1012ULACM delivers 12 VDC at 10 A through eight individually fused outputs, making it suitable for access-control panels, cameras and other low-voltage security devices that require distributed power from a single unit. It operates from a 115 VAC 60 Hz mains supply and is UL294 and CUL listed for life-safety and security applications.

Battery Leads and Cam Lock Included

Supplied battery leads allow connection of backup batteries so connected equipment remains powered during mains interruptions, while the cam lock secures the enclosure door against unauthorised access. These two items are the only bundled accessories noted in the manufacturer data.

Steel Enclosure with Wall-Mount Dimensions

The grey-finished steel enclosure measures 12.00 in wide, 15.5 in high and 4.50 in deep, providing a rigid housing that can be surface-mounted on a wall or backboard. The cam-locked door and internal fuse arrangement mean routine fuse replacement and battery checks can be performed without removing the entire unit from the mounting surface.

Pontos fortes

  • Delivers 10A at 12VDC for reliable access control
  • Eight individually fused outputs protect each circuit
  • UL294 and CUL listed for safety compliance
  • Steel enclosure with cam lock secures installation
  • 115VAC 60Hz input suits standard mains supply

Especificações

TypeOther

Perguntas sobre este artigo

How often do the eight fuses need checking or replacement under normal operation?

The eight individual fuses protect each output circuit; they only require replacement if a specific circuit trips due to a short or overload, so routine checking is not scheduled.

What is the first limit reached when the unit runs continuously at full 10 A load?

The 10 A total output current rating is the primary limit; sustained loads above this will cause the protection fuses to open.

How much heat and noise does the steel enclosure produce during all-day 12 VDC operation?

The passively cooled steel enclosure (12.00 in wide, 15.5 in high, 4.50 in deep) dissipates heat silently with no fan, so audible noise is negligible.

Também nesta secção

Os clientes também compararam

Mesma prateleira, mesma finalização da compra — oito moedas e uma taxa bloqueada durante 30 minutos.