Eaton
Eaton 5P1550G 1550 VA 1100 W 8 Outlet Tower UPS
Tower UPS delivering 1550 VA and 1100 W through eight IEC C13 outlets with 4-minute full-load runtime
- International Version208/230V
- Input Voltage Range150 V AC to 294 V AC Adjustable 160 V AC to 294 V AC
- Output Voltage102 V AC to 132 V AC On Utility 200 V AC Nominal 208 V AC No
- Outlets8 x IEC 60320 C13
- Battery Run Time0.07 Hour 0.22 Hour
- Interface PortRJ-45 RS-232 USB
- 1550 VA 1100 W protects critical equipment
- Eight IEC 60320 C13 outlets power multiple devices
- Adjustable input 150 V to 294 V handles unstable mains
- Tower form factor fits rack or floor space
- ENERGY STAR certified reduces energy cost
Capacity and topology
The Eaton 5P1550G is a tower-format uninterruptible power supply rated at 1550 VA and 1100 W. It delivers sine-wave output at a default 230 V with selectable nominal voltages of 200, 208, 220, 230 and 240 V AC. Eight IEC 60320 C13 outlets distribute protected power to connected equipment. The unit accepts an input range of 150 V to 294 V AC and includes a single IEC 60320 C14 inlet.
Suitable loads and limitations
This UPS suits servers, network switches and storage arrays that require pure sine-wave output and runtime at full load of approximately .07 hour. At half load the battery extends to roughly .22 hour. Environments needing longer autonomy, higher power capacity or hard-wired input and output connections should evaluate larger or modular platforms instead.
Deciding specification
The 1100 W real-power rating is the single figure that determines whether the 5P1550G can support a given load. If the combined draw of all attached devices exceeds 1100 W the UPS will overload; if it remains below that threshold the unit will provide battery backup and voltage regulation as specified.
Pontos fortes
- 1550 VA 1100 W protects critical equipment
- Eight IEC 60320 C13 outlets power multiple devices
- Adjustable input 150 V to 294 V handles unstable mains
- Tower form factor fits rack or floor space
- ENERGY STAR certified reduces energy cost
Especificações
| Brand | EATON |
|---|---|
| Model | 5P |
| International Version | 208/230V |
| Input Voltage Range | 150 V AC to 294 V AC Adjustable 160 V AC to 294 V AC |
| Output Voltage | 102 V AC to 132 V AC On Utility 200 V AC Nominal 208 V AC Nominal 220 V AC Nominal 230 V AC Nominal 240 V AC Nominal |
| Outlets | 8 x IEC 60320 C13 |
| Battery Run Time | 0.07 Hour 0.22 Hour |
| Interface Port | RJ-45 RS-232 USB |
| Weight | 37.45 |
| Peso de envio | 16.78 kg |
| Dimensões da embalagem | 559 × 330 × 254 mm |
Perguntas sobre este artigo
How do I decide between the 1550 VA and 1100 W ratings when sizing my load?
Use the 1100 W figure for real power draw of your equipment; the 1550 VA rating covers apparent power including reactive loads. Stay under 1100 W total to avoid overload.
What does the 4 minute backup time at full load mean for my servers?
At the full 1100 W load the unit runs for about 4 minutes (0.07 hour); at lighter loads the runtime extends to roughly 13 minutes (0.22 hour).
Which management interface should I use, USB or the RJ-45 RS-232 port?
USB is simpler for direct PC or server monitoring; the RJ-45 RS-232 port suits serial-based management cards or legacy automation systems.