Aceitamos criptomoeda — para que as moedas que detém possam comprar material informático real.Pague em cripto, gaste-a em material informático real. Envio seguro gratuito para todo o mundo acima de 399 $. Caixas neutras, sem marca, expedidas a partir da Alemanha.Envio seguro gratuito acima de 399 $. A sua taxa fica bloqueada durante 30 minutos assim que abre a finalização da compra.Taxa bloqueada 30 minutos. Cada artigo é selado, o seu número de série é verificado, e está coberto por uma garantia de 24 meses.Selado, garantido 24 meses.

Artigos guardados Iniciar sessão

Vertiv

Vertiv GXT5-2000LVRT2UXLTAAN UPS 2000VA 1800W 120V 2U Rack Tower

SKU CH-32WD-QVPP0 MPN GXT5-2000LVRT2UXLTAAN

Double-conversion 2000VA/1800W UPS with 0.9 power factor, seven outlets (one L5-20R, six 5-20R) and included network management card in a 2U rack/tower form factor

  • International Version120V
  • Input Voltage Range60-150V
  • Input ConnectionNEMA L5-20P A
  • VA Rating2000VA
  • Watts1800W
  • Output Voltage110/115/120/125VAC; (user-configurable); +/-3%

As versões riscadas existem, mas não estão disponíveis aqui.

  • Double-conversion topology protects sensitive loads from power disturbances
  • 9 output power factor delivers 1800 W of usable capacity for dense equipment
  • Energy Star 2.0 certification reduces operating cost over the unit life
  • Rack or tower form factor fits 2U space in either orientation
  • Network management card plus USB and serial ports enable remote monitoring

2000VA 120V Double-Conversion UPS

The Vertiv GXT5-2000LVRT2UXLTAAN is a 2U rack-tower UPS delivering 2000VA and 1800W with a 0.9 output power factor. It operates from a 60-150V input range through a NEMA L5-20P plug and provides user-configurable output at 110, 115, 120 or 125VAC. The unit includes a factory-installed RDU101 network management card.

IT environments needing TAA compliance

This UPS suits IT managers deploying TAA-compliant infrastructure in 2U rack or tower spaces who require remote monitoring via the included network card, USB, serial or EPO connections. Buyers without a 20A twist-lock input circuit, or who need 120V input compatibility, should look at other models. Environmental sensors for temperature, humidity and leak detection support monitored installations.

0.9 output power factor at 1800W

The 0.9 power factor means the 2000VA rating yields 1800W of real power, a higher usable capacity than lower-factor designs at the same VA. This single figure determines how many modern power-factor-corrected loads the UPS can support during an outage. Energy Star 2.0 certification confirms efficient operation within the specified 104°F and 9842.52 ft limits.

Pontos fortes

  • Double-conversion topology protects sensitive loads from power disturbances
  • 9 output power factor delivers 1800 W of usable capacity for dense equipment
  • Energy Star 2.0 certification reduces operating cost over the unit life
  • Rack or tower form factor fits 2U space in either orientation
  • Network management card plus USB and serial ports enable remote monitoring

Especificações

BrandVertiv
ModelGXT5-2000LVRT2UXLTAAN
International Version120V
Input Voltage Range60-150V
Input ConnectionNEMA L5-20P A
VA Rating2000VA
Watts1800W
Output Voltage110/115/120/125VAC; (user-configurable); +/-3%
Outlets7
Outlet Type1 x NEMA L5-20R, 6 x NEMA 5-20R
Dimensions3.4" x 16.9" x 18.5"
Weight47.5 lbs.
Peso de envio26.63 kg
Dimensões da embalagem617 × 569 × 262 mm

Outras versões deste modelo

Mais 5 nesta gama

Mesma família, memória, ventoinha ou frequência diferentes — compare antes de decidir.

Perguntas sobre este artigo

How can I confirm the GXT5-2000LVRT2UXLTAAN is operating correctly after installation?

The LCD display shows real-time status including load percentage, battery charge, and input/output voltage; a green "Online" indicator confirms double-conversion mode is active.

What ships with the GXT5-2000LVRT2UXLTAAN and what must I purchase separately?

The unit includes the RDU101 network card, USB and serial cables, rack-mount rails, and tower feet; input cord (NEMA L5-20P) and any output cords for NEMA 5-20R or L5-20R outlets are not included.

Which output voltage setting — 110, 115, 120, or 125 VAC — should I select for my 120 V equipment?

Choose 120 VAC; the UPS regulates output to ±3 % around the selected value, matching standard North American 120 V loads.

Também nesta secção

Os clientes também compararam

Mesma prateleira, mesma finalização da compra — oito moedas e uma taxa bloqueada durante 30 minutos.