我們接受加密貨幣付款 — 讓您持有的幣種也能買到真正的硬體設備。以加密貨幣付款,直接購入真正的硬體設備。 全球訂單滿 US$399,即享免費保險運送。簡約外箱,不印任何品牌標誌,從德國出貨。訂單滿 US$399,即享免費保險運送。 結帳一開始,您的匯率即鎖定 30 分鐘。匯率鎖定 30 分鐘。 每件商品皆原廠密封、序號經過核對,並享有 24 個月保固。原廠密封,保固 24 個月。

追蹤清單 登入

DELL

DELL PX05SVB192Y 1.92TB SAS 2.5" enterprise SSD

SKU CH-9G12-AAC9P

1.92 TB enterprise SSD with 12 Gb/s SAS interface fits 2.5-inch bays in Dell PowerEdge servers from R210 through R930

  • 92 TB capacity supports large enterprise workloads
  • 12 Gb/s SAS interface delivers high-throughput data transfer
  • 5 inch form factor fits standard server drive bays
  • Mixed-use endurance handles balanced read and write demands
  • Compatible with Dell PowerEdge R210 through R930 servers

1.92TB SAS enterprise SSD

This 1.92TB SAS solid-state drive fits 2.5-inch bays in Dell PowerEdge servers from the R210 through R930 families. It is built for mixed-use workloads that demand consistent throughput and low latency. The 12Gb/s interface matches backplanes in the listed platforms without adapters.

Thermals noise and power

The drive has no moving parts, so it runs silently and adds minimal heat to a populated chassis. Power draw stays within the standard SAS 2.5-inch envelope, leaving headroom for other devices on the same backplane. No auxiliary cooling or special airflow routing is required.

Dell part-number validation

The V0K7V part number guarantees firmware alignment with the compatible server list, avoiding mismatch alerts during POST. No extra cables, brackets or licence keys ship with the unit. Installation is a direct swap into any supported bay.

商品特色

  • 92 TB capacity supports large enterprise workloads
  • 12 Gb/s SAS interface delivers high-throughput data transfer
  • 5 inch form factor fits standard server drive bays
  • Mixed-use endurance handles balanced read and write demands
  • Compatible with Dell PowerEdge R210 through R930 servers

商品規格

本商品目前尚未公佈規格。

商品問答

How do I install the PX05SVB192Y in a Dell R630, and what step is often missed?

Slide the 2.5 inch SAS drive into a hot-swap bay until the carrier clicks, then verify the 12Gb/s link negotiates in the RAID controller BIOS; skipping the link-speed check is the common error.

What maintenance or replacement will the 1.92TB MU SSD need later?

Monitor SMART wear indicators; when the mixed-use endurance budget is exhausted the drive must be replaced, as no user-serviceable parts exist inside.

What limit appears first on the PX05SVB192Y during sustained writes?

The 12Gb/s SAS interface caps sustained throughput, so the bus saturates before the internal NAND reaches its steady-state write ceiling.

同類商品

顧客也比較過

同一分類,同一套結帳流程 — 支援八種加密貨幣,匯率鎖定 30 分鐘。