Eaton 9SX2000G 2000VA 1800W 208V UPS 8 C13 Outlets

SKU CH-YV9C-Q1JZB MPN 9SX2000G

Online double-conversion UPS delivers 2000 VA / 1800 W with eight C13 outlets and 10.40 min runtime

  • Input Voltage Range190 V AC - 276 V AC
  • Output Voltage200 V AC 208 V AC 220 V AC 230 V AC 240 V AC
  • Outlets8 x IEC 60320 C13
  • 2000 VA capacity supports critical loads
  • 1800 W output handles dense power demands
  • 8 C13 outlets connect multiple servers
  • 190–276 V AC input tolerates unstable mains
  • 40 min runtime at full load protects work

2000VA 208V Online UPS

The Eaton 9SX2000G is a double-conversion UPS delivering 2000VA and 1800W of continuous power. It operates from a 208V nominal input through an L6-20P cord and provides eight IEC 60320 C13 outlets for protected equipment.

Rack and tower environments needing 208V backup

This unit suits server rooms, network closets and edge sites that require clean sine-wave output at 200, 208, 220, 230 or 240V AC. Sites without 208V utility service or that need NEMA-style outlets should select a model built for their local voltage and receptacle standard.

10.40-minute runtime at full load

The internal battery provides 10.40 minutes of stand-by time when the UPS is supplying its rated 1800W. Extended-run capability allows additional battery cabinets to be added when longer autonomy is required.

商品特色

  • 2000 VA capacity supports critical loads
  • 1800 W output handles dense power demands
  • 8 C13 outlets connect multiple servers
  • 190–276 V AC input tolerates unstable mains
  • 40 min runtime at full load protects work

商品規格

BrandEATON
Input Voltage Range190 V AC - 276 V AC
Output Voltage200 V AC
208 V AC
220 V AC
230 V AC
240 V AC
Outlets8 x IEC 60320 C13
出貨重量35.70 kg
包裝尺寸574 × 488 × 411 mm

商品問答

What type of input plug and cord length does the 9SX2000G require for a 208 V supply?

The unit ships with an L6‑20P plug on an 8‑foot input cord for a 208 V AC source.

Which step is most often missed when installing this tower UPS?

Users frequently forget to connect and charge the internal battery modules before powering on the UPS for the first time.

When will the internal batteries need replacement in this 2000 VA model?

Expect to replace the battery modules every three to five years, depending on temperature and discharge cycles.