我們接受加密貨幣付款 — 讓您持有的幣種也能買到真正的硬體設備。以加密貨幣付款,直接購入真正的硬體設備。 全球訂單滿 US$399,即享免費保險運送。簡約外箱,不印任何品牌標誌,從德國出貨。訂單滿 US$399,即享免費保險運送。 結帳一開始,您的匯率即鎖定 30 分鐘。匯率鎖定 30 分鐘。 每件商品皆原廠密封、序號經過核對,並享有 24 個月保固。原廠密封,保固 24 個月。

追蹤清單 登入

ICY DOCK

ICY DOCK MB014SP-B 4-bay 2.5" SATA/SAS rack server

SKU CH-GYWY-6AYYD

Holds four 2.5" SATA or SAS drives in a single 5.25" bay with tool-less hot-swap trays and a 40mm fan

  • TypeRack
  • Supports four 2.5" SAS/SATA drives up to 9.5 mm thick
  • Fits a standard 5.25" bay for quick system integration
  • Tray-less hot-swap design swaps bare drives without tools or screws
  • Individual power buttons and robust ejection levers per drive bay
  • 40 mm adjustable-speed cooling fan with on/off jumper control

Four-bay 2.5" hot-swap enclosure

The ICY DOCK MB014SP-B fits four 2.5 inch SATA or SAS drives into a single 5.25 inch bay. Each bay accepts drives from 5 mm to 9.5 mm thick. A tray-less and door-less mechanism lets you swap bare drives without tools or screws. The unit is built with a full metal chassis and industrial ABS plastic.

Suits dense server or workstation builds

This enclosure serves administrators who need multiple hot-swappable drives in limited rack space. It requires a SAS host for 12 Gbps SAS operation and a standard external 5.25 inch bay. Builders without a SAS controller or an available 5.25 inch slot cannot use it. Buyers needing more than four drive bays must look elsewhere.

Cooling fan and locking cables included

A 40 mm fan with adjustable speed control and an on/off jumper provides active airflow across the drives. Individual power buttons and robust ejection mechanisms improve drive management. SATA data and power cables with locking latches are supplied to secure connections against vibration. No additional software or mounting rails are bundled.

商品特色

  • Supports four 2.5" SAS/SATA drives up to 9.5 mm thick
  • Fits a standard 5.25" bay for quick system integration
  • Tray-less hot-swap design swaps bare drives without tools or screws
  • Individual power buttons and robust ejection levers per drive bay
  • 40 mm adjustable-speed cooling fan with on/off jumper control

商品規格

TypeRack

商品問答

Which host interface and cable type do I need to connect the enclosure's four drive bays?

The unit uses a single-channel SAS interface; a SAS host controller and locking-latch SATA data and power cables are required for full 12 Gbps SAS or 6 Gbps SATA operation.

Can I keep my existing 5.25-inch bay drives while adding this four-bay enclosure?

Yes, it installs into any standard external 5.25-inch bay, so legacy optical drives or other 5.25-inch devices can remain in adjacent bays.

How do I verify each drive is powered and communicating after installation?

Individual drive power buttons and the 40 mm fan with adjustable speed control provide immediate visual and audible confirmation that each bay is active.

同類商品

顧客也比較過

同一分類,同一套結帳流程 — 支援八種加密貨幣,匯率鎖定 30 分鐘。