ICY DOCK
ICY DOCK MB994SP-4S 4-bay 2.5" SAS drive bay adapter ssd accessory
Four-bay internal adapter holds 2.5-inch SAS drives in a single 5.25-inch bay
- Fits four 2.5" drives in one 5.25" bay
- SAS interface supports high-speed enterprise drives
- Tool-less trays allow quick drive swaps
- Matt black finish matches server chassis aesthetics
- Built to California Prop 65 compliance standards
4-bay 2.5" SAS drive bay adapter
The ICY DOCK MB994SP-4S installs four 2.5-inch SAS drives into a single 5.25-inch front bay. It suits server and workstation builders who need dense, hot-swappable storage without sacrificing external drive slots.
Thermals noise and power draw in normal use
The all-metal tray conducts heat from each drive directly to the chassis airflow path. No onboard fan means silent operation and zero additional power draw beyond the drives themselves.
How it fits into a build
A single 5.25-inch bay and a backplane or controller with SAS connectors are required. The adapter frees three 3.5-inch internal bays that would otherwise hold individual drive cages.
商品特色
- Fits four 2.5" drives in one 5.25" bay
- SAS interface supports high-speed enterprise drives
- Tool-less trays allow quick drive swaps
- Matt black finish matches server chassis aesthetics
- Built to California Prop 65 compliance standards
商品規格
本商品目前尚未公佈規格。
商品問答
How do I install the MB994SP-4S and what step is often missed?
Mount the adapter into a standard 5.25" front bay, secure it with screws, then insert up to four 2.5" SAS drives into the trays. The step often missed is connecting each drive to a SAS backplane or controller with the correct cable orientation.
What maintenance or replacement will the MB994SP-4S need later?
The trays and latch mechanisms are the only moving parts. Over time the plastic ejector clips can wear or snap, so keep spare trays on hand. No fans or filters are present, so no cleaning schedule is required.
What limit appears first when the MB994SP-4S runs under sustained load?
Because the enclosure has no active cooling, drive temperature is the first bottleneck. Extended heavy I/O will raise 2.5" SAS drive temps until thermal throttling engages, limiting sustained throughput.
同類商品
顧客也比較過
同一分類,同一套結帳流程 — 支援八種加密貨幣,匯率鎖定 30 分鐘。
Black Box Corporation DisplayPort to DVI Fibre Optic Cable 15 ft 4.5 m 1.35 GB/s
- Consumer Electronics



