Programmable DC bench supply delivering 0 to 200 volts at 9 amps with 1800 watts output, RS-232 and RS-485 interfaces, and full protection suite

  • TypeMATRIX MPS-1800S-200-9 High Voltage Programmable DC Power Su
  • Watts1800 watts
  • Engine BrandMATRIX
  • Voltage200 volts
  • Size/Dimensions14 in x 19 in x 3.5 in
  • Input VoltageMATRIX MPS-1800S-200-9 High Voltage Programmable DC Power Su
  • Programmable output up to 200V and 9A for flexible test setups
  • 1800W continuous power handles demanding industrial loads
  • Five-digit simultaneous voltage and current display enables precise monitoring
  • Comprehensive OVP, OCP, OTP and short-circuit protection safeguards equipment
  • RS-232 and RS-485 interfaces allow automated remote control

Matrix MPS-1800S-200-9 programmable DC supply

The Matrix MPS-1800S-200-9 is a programmable bench DC power supply rated for 1800 watts with a 0-200 volt and 0-9 amp output range. It targets engineers and technicians who need precise, adjustable power for development, test or production environments.

Upgrade from fixed-output or lower-power units

This model replaces fixed-voltage supplies or lower-wattage programmable units when a project demands both higher voltage headroom and fine current control. The jump is worth it when simultaneous five-digit voltage and current readout, preset recall and remote compensation are required for repeatable results.

Verify AC service and communication needs

Confirm the site provides single-phase AC 220V ±10% at 50 Hz before ordering. Ensure the test rack can accommodate a 14 by 19 by 3.5 inch 2U form factor and that RS-232 or RS-485 interfaces match the control software in use.

商品特色

  • Programmable output up to 200V and 9A for flexible test setups
  • 1800W continuous power handles demanding industrial loads
  • Five-digit simultaneous voltage and current display enables precise monitoring
  • Comprehensive OVP, OCP, OTP and short-circuit protection safeguards equipment
  • RS-232 and RS-485 interfaces allow automated remote control

商品規格

TypeMATRIX MPS-1800S-200-9 High Voltage Programmable DC Power Supply 200V 9A 1800W High-Power with OVP, OCP, OTP, Short Circuit Protection, Input AC 220V 50Hz, adjustable bench dc power supply 1800w variable lab dc power supply switching dc power supply
Watts1800 watts
Engine BrandMATRIX
Voltage200 volts
Size/Dimensions14 in x 19 in x 3.5 in
Input VoltageMATRIX MPS-1800S-200-9 High Voltage Programmable DC Power Supply 200V 9A 1800W High-Power with OVP, OCP, OTP, Short Circuit Protection, Input AC 220V 50Hz
Output VoltageMPS-1800S-200-9, MATRIX MPS-1800S-200-9 High Voltage Programmable DC Power Supply 200V 9A 1800W High-Power with OVP, OCP, OTP, Short Circuit Protection, Input AC 220V 50Hz, adjustable bench dc power supply 1800w variable lab dc power supply switching dc power supply
Output AmpsMPS-1800S-200-9, MATRIX MPS-1800S-200-9 High Voltage Programmable DC Power Supply 200V 9A 1800W High-Power with OVP, OCP, OTP, Short Circuit Protection, Input AC 220V 50Hz
Input Amps2U, MATRIX MPS-1800S-200-9 High Voltage Programmable DC Power Supply 200V 9A 1800W High-Power with OVP, OCP, OTP, Short Circuit Protection, Input AC 220V 50Hz
Styleadjustable bench dc power supply 1800w variable lab dc power supply switching dc power supply
SeriesMPS-1800S-200-9
Operating Frequencynot_applicable
Regulationnot_applicable
RippleMATRIX MPS-1800S-200-9 High Voltage Programmable DC Power Supply 200V 9A 1800W High-Power with OVP, OCP, OTP, Short Circuit Protection, Input AC 220V 50Hz
Featuresadjustable bench dc power supply 1800w variable lab dc power supply switching dc power supply, MATRIX MPS-1800S-200-9 High Voltage Programmable DC Power Supply 200V 9A 1800W High-Power with OVP, OCP, OTP, Short Circuit Protection, Input AC 220V 50Hz
Parts3 Years
Labor3 Years

商品問答

What rack space and clearance does the 14 in x 19 in x 3.5 in chassis require?

The unit occupies 2U height (3.5 in) in a standard 19 in rack; allow at least 14 in depth behind the front panel for the body and cable bend radius.

What is the correct AC input wiring sequence before powering the MPS-1800S-200-9?

Verify single-phase 220 V ±10 % at 50 Hz, connect live, neutral and protective earth to the rear terminal block in that order, then engage the front-panel key lock to prevent accidental output changes.

Which consumable parts should be inspected after extended full-load operation?

The internal cooling fans are the only moving components; inspect airflow and bearing noise annually and replace if speed drops or vibration appears.