我們接受加密貨幣付款 — 讓您持有的幣種也能買到真正的硬體設備。以加密貨幣付款,直接購入真正的硬體設備。 全球訂單滿 US$399,即享免費保險運送。簡約外箱,不印任何品牌標誌,從德國出貨。訂單滿 US$399,即享免費保險運送。 結帳一開始,您的匯率即鎖定 30 分鐘。匯率鎖定 30 分鐘。 每件商品皆原廠密封、序號經過核對,並享有 24 個月保固。原廠密封,保固 24 個月。

追蹤清單 登入

Tripp Lite

Tripp Lite SMART2200VS 2200VA 1600W UPS

SKU CH-8NR4-61TVC MPN SMART2200VS

Line-interactive tower UPS delivers 2200VA / 1600W with automatic voltage regulation from 79V to 147V, nine NEMA outlets, RS-232 and USB management.

  • Input Voltage Range120 V
  • Input Frequency60 Hz +/- 3 Hz
  • VA Rating2200 VA
  • Watts1600 Watts
  • Output Voltage120V AC
  • Outlets9
  • 2200VA capacity powers servers and networking gear
  • 1600 watt output supports demanding telecom equipment
  • Automatic voltage regulation corrects brownouts to 79V and overvoltages to 147V
  • 9 minutes runtime at half load keeps systems running during short outages
  • USB and RS-232 ports enable simultaneous management and monitoring

SmartPro 2200VA Tower UPS

The Tripp Lite SMART2200VS is a new line-interactive tower UPS rated at 2200VA and 1600 watts. It accepts 120V input at 60Hz and delivers 120V AC output through nine outlets, seven of which are NEMA 5-15R and two are NEMA 5-15/20R. The unit uses a valve-regulated lead-acid battery that recharges to 90 percent in two to four hours.

Suited for server and network racks needing

This UPS fits environments where floor space is limited, occupying 106 square inches with a height of 14.25 inches. It provides full-load runtime of seven minutes and half-load runtime of 19 minutes, making it appropriate for orderly shutdowns of attached equipment. It is not for buyers who need extended runtime at full load beyond the stated figures or who require input voltage ranges outside 120V.

Automatic voltage regulation from 79V to 147V

The UPS maintains 120V nominal output during brownouts down to 79V and overvoltages up to 147V without switching to battery. This regulation range is the specification that determines whether the unit will protect connected gear through typical utility fluctuations. Communication is handled via RS-232 and USB ports with included management software.

商品特色

  • 2200VA capacity powers servers and networking gear
  • 1600 watt output supports demanding telecom equipment
  • Automatic voltage regulation corrects brownouts to 79V and overvoltages to 147V
  • 9 minutes runtime at half load keeps systems running during short outages
  • USB and RS-232 ports enable simultaneous management and monitoring

商品規格

BrandTRIPP LITE
SeriesSmartPro
ModelSMART2200VS
Input Voltage Range120 V
Input Frequency60 Hz +/- 3 Hz
VA Rating2200 VA
Watts1600 Watts
Output Voltage120V AC
Outlets9
Outlet Type7 NEMA 5-15R and 2 NEMA 5-15/20R
Battery TypeValve Regulated Lead Acid (VRLA)
Battery Run TimeFull load runtime: 7 minutes (2200VA)
Half load runtime: 19 minutes (1100VA)
Battery Recharge Time2-4 hours to 90%
AlarmsAudible alarm indicates power failure conditions (4 short beeps every 10 seconds), overload (continuous short beeps) and low battery (continuous tone)
Interface PortRS-232, USB
Management SoftwareYES
ApprovalsUL1778 (USA), cUL (Canada), Class A (emissions), NOM (Mexico)
Surge Energy Rating480 Joules
Features2200VA / 1600 watt output capacity accommodates a variety of server, networking and telecom devices
High power density 2.2kVA UPS system occupies only 106 square inches of floorspace with a height of only 14.25 inches
Compatible with North American 120V / 60 Hz power as found in the USA, Canada and Mexico
Offers 7 minutes runtime with a full load of 2200VA and 19 minutes with a half load of 1100VA
Line interactive voltage regulation corrects severe brownouts and overvoltages from 79 to 147v back to normal 120v levels without using battery power
9 total outlets (7 NEMA5-15R; 2 NEMA5-1
Dimensions14.25" x 9.25" x 12.00"
Weight52.4 lbs.
Package ContentsC44243
VA2200 VA
出貨重量27.22 kg
包裝尺寸508 × 406 × 381 mm

其他版本

同系列還有 5 款

同系列產品,記憶體、散熱器或時脈不同 — 下單前請先比較。

商品問答

How long will the battery last at full 2200 VA load?

The battery provides 7 minutes of runtime at full 2200 VA load and 19 minutes at half load of 1100 VA.

What audible alarms sound during continuous operation?

The unit emits 4 short beeps every 10 seconds on power failure, continuous short beeps on overload and a continuous tone when the battery is low.

Which communication cables must the buyer already have to connect the UPS?

The UPS includes RS-232 and USB ports; you need a standard RS-232 serial cable or a USB cable to link it to a computer for management.

同類商品

顧客也比較過

同一分類,同一套結帳流程 — 支援八種加密貨幣,匯率鎖定 30 分鐘。