我們接受加密貨幣付款 — 讓您持有的幣種也能買到真正的硬體設備。以加密貨幣付款,直接購入真正的硬體設備。 全球訂單滿 US$399,即享免費保險運送。簡約外箱,不印任何品牌標誌,從德國出貨。訂單滿 US$399,即享免費保險運送。 結帳一開始,您的匯率即鎖定 30 分鐘。匯率鎖定 30 分鐘。 每件商品皆原廠密封、序號經過核對,並享有 24 個月保固。原廠密封,保固 24 個月。

追蹤清單 登入

Tripp Lite

Tripp Lite SU1000RTXLCD2U 1000VA 900W 120V Double-Conversion UPS 2U Rack/Tower

SKU CH-NFVR-PEMY5 MPN SU1000RTXLCD2U

Double-conversion sine-wave UPS delivers 900 W from eight NEMA 5-15R outlets with hot-swappable battery, LCD, USB, serial and optional network card in a 2U rack/tower chassis

  • International Version120V
  • Input ConnectionNEMA 5-15P
  • VA Rating1000 VA
  • Watts900 Watts
  • Output Voltage120V
  • Outlets8
  • Double-conversion topology delivers clean sine-wave power to sensitive equipment
  • 1000 VA / 900 W capacity supports critical servers and network gear
  • 8 NEMA 5-15R outlets provide ample connections for rack or tower deployments
  • Hot-swappable VRLA batteries allow replacement without interrupting connected loads
  • LCD panel plus USB, RS-232 and SNMP slot enable local and remote monitoring

Tripp Lite 1000VA Double-Conversion UPS

The Tripp Lite SU1000RTXLCD2U is a 1000VA 900W double-conversion online UPS that delivers continuous sine-wave power at 120V. It fits a 2U rack or tower form factor and provides eight NEMA 5-15R outlets for connected equipment. The unit suits network closets, server rooms or workstations that require zero transfer time during power events.

Verify 120V supply and NEMA 5-15P input

Confirm your facility provides a 120V branch circuit with a NEMA 5-15P receptacle for the UPS input plug. Ensure the combined load of attached devices does not exceed 900W or 1000VA. Check that the 2U rack space or tower footprint accommodates the 3.41" x 17.33" x 17.72" dimensions and that operating temperature stays within 32° to 104°F.

Hot-swappable battery and optional network card

The VRLA battery is hot-swappable, allowing replacement without powering down connected loads. A dedicated slot accepts an optional SNMP/Web interface card for remote monitoring. USB, RS-232 and contact-closure ports provide additional management connectivity. The LCD panel reports runtime, load and voltage status locally.

商品特色

  • Double-conversion topology delivers clean sine-wave power to sensitive equipment
  • 1000 VA / 900 W capacity supports critical servers and network gear
  • 8 NEMA 5-15R outlets provide ample connections for rack or tower deployments
  • Hot-swappable VRLA batteries allow replacement without interrupting connected loads
  • LCD panel plus USB, RS-232 and SNMP slot enable local and remote monitoring

商品規格

BrandTRIPP LITE
SeriesSMARTONLINE Series
ModelSU1000RTXLCD2U
International Version120V
Input ConnectionNEMA 5-15P
VA Rating1000 VA
Watts900 Watts
Output Voltage120V
Outlets8
Outlet Type(8) NEMA 5-15R
Battery TypeValve Regulated Lead Acid (VRLA)
Battery Run TimeFull load runtime: 6.3 min (900 Watts)
Half load runtime: 18.2 min (450 Watts)
Battery Recharge TimeLess than 3 hour(s) recharge to 90%
Interface Port(1) Contact closure; (1) RS-232; (1) Slot for SNMP/Web interface; (1) USB
ApprovalsTested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category B (EMI); ROHS (Restriction of Hazardous Substances)
RackmountableYes
Surge Energy Rating190 Joules
TemperatureOperating Temperature Range: 32° to 104°F (0° to 40°C)
Storage Temperature Range: With battery: 32° to 104°F (0° to 40°C); without battery: -13° to 131°F (-25° to 55°C)
Humidity0-96% non-condensing
Dimensions3.41" x 17.33" x 17.72"
Weight36.38 lbs.
出貨重量19.07 kg
包裝尺寸594 × 511 × 231 mm

其他版本

同系列還有 5 款

同系列產品,記憶體、散熱器或時脈不同 — 下單前請先比較。

商品問答

What comes in the box with the SU1000RTXLCD2U and what must I buy separately?

The UPS ships with 8 NEMA 5-15R outlets, a NEMA 5-15P input cord, USB, RS-232 and contact-closure cables, and rack-mount hardware. A network management card for the SNMP slot and any external battery packs are sold separately.

Should I choose the 1000 VA / 900 W model or a different capacity?

This unit delivers 1000 VA and 900 W at 120 V. Select it when your connected load is at or below 900 W; if the load exceeds that figure, a higher-capacity UPS is required.

What does the 900 W rating mean for actual runtime?

At a full 900 W load the battery lasts 6.3 minutes; at half load (450 W) it lasts 18.2 minutes. Recharge to 90 % takes less than 3 hours.