CyberPower
CyberPower PDU15MHVIEC8FNET PDU 1U 15A 8×C13 C14 10ft
Monitored 1U rack PDU distributes 200-240V power to eight C13 outlets from a single C14 input with SNMP remote management and LCD metering
- TypeMonitored
- Rack Size1U
- StyleRackmount, Vertical Rackmount, Under-Counter
- Remote Management ProtocolTCP/IP, UDP, DHCP, SNMP, HTTP
- CertificationsUL60950_1 , CSA C22.2, FCC Class A
- ROHSYes
- Monitored PDU with SNMP, HTTP and DHCP for remote power management
- Eight IEC-320 C13 outlets fed from one C14 inlet simplify rack wiring
- 1U rackmount, vertical or under-counter styles fit diverse cabinet layouts
- 15 A input with 12 A derated protection guards connected equipment
- LCD shows real-time amps, volts, kilowatts and IP address at a glance
Monitored PDU for rack environments
The CyberPower PDU15MHVIEC8FNET is a 1U monitored power distribution unit built for datacenters and electrically demanding installations. It accepts 200-240V input through an IEC-320 C14 plug with a 10 ft cord and delivers the same voltage range to eight IEC-320 C13 outlets. Remote management runs over TCP/IP, UDP, DHCP, SNMP and HTTP via an RJ45 Ethernet port.
15A maximum with 12A derated headroom
The unit carries a 15A maximum input current that is regulatory derated to 12A for UL and 10A for CE, giving clear headroom limits for continuous loads. Overload protection trips at the 15A rating while the derated figures define the practical continuous capacity. An LCD shows real-time current, voltage, power consumption and the IP address for quick local verification.
SNMP and HTTP over Ethernet only
Network monitoring and outlet control rely exclusively on the RJ45 Ethernet connection using SNMP, HTTP, TCP/IP, UDP and DHCP; no other remote interfaces are present. The metal chassis operates from 0 to 45 °C, up to 95 % relative humidity and at elevations up to 4500 m. Certifications include UL 60950-1, CSA C22.2 and FCC Class A with RoHS compliance.
Puntos fuertes
- Monitored PDU with SNMP, HTTP and DHCP for remote power management
- Eight IEC-320 C13 outlets fed from one C14 inlet simplify rack wiring
- 1U rackmount, vertical or under-counter styles fit diverse cabinet layouts
- 15 A input with 12 A derated protection guards connected equipment
- LCD shows real-time amps, volts, kilowatts and IP address at a glance
Especificaciones
| Brand | CyberPower |
|---|---|
| Model | PDU15MHVIEC8FNET |
| Type | Monitored |
| Rack Size | 1U |
| Style | Rackmount, Vertical Rackmount, Under-Counter |
| Remote Management Protocol | TCP/IP, UDP, DHCP, SNMP, HTTP |
| Certifications | UL60950_1 , CSA C22.2, FCC Class A |
| ROHS | Yes |
| Input Voltage | 200 - 240V |
| Input Frequency | 50/60 Hz |
| Maximum Input Current | 15A |
| Regulatory Derated Input Current | 12A |
| Input Connector(s) | IEC-320 C14 |
| Cord Length | 10 ft |
| Output Voltage | 200V - 240V |
| Output Connector(s) | 8 x IEC-320 C13 |
| Overload Protection | 15A (Derated 12A-UL/10A-CE) |
| Operating Environment | 0 - 45 °C |
| Operating Relative Humidity | 0 - 95% |
| Operating Elevation | 0 - 4500 m |
| Storage Temperature | -15 - 45 °C |
| Storage Elevation | 0 - 15000 m |
| Features | Monitored PDU with SNMP Network interface Digital Display (Load, Voltage, KW, and IP Address) 8 IEC-320 C13 Receptacles (8 Front) Single Phase 200-240V AC - 50/60Hz / 15-amp electrical capacity IEC-320 C14 Plug with 10-ft. power cord Automatic events notification via Email and SNMP Trap User Upgradeable Firmware 1U rack mount Rugged, industrial-grade metal housing |
| Dimensions | 17.05" x 1.75" x 4.41" (H x W x D) |
| Weight | 3.53 lbs. |
| Peso de envío | 3.36 kg |
| Dimensiones del paquete | 498 × 251 × 61 mm |
Preguntas sobre este artículo
Will the C14 inlet and 12 A derated limit work with my existing 208 V rack circuit?
Yes — the unit accepts 200–240 V at 50/60 Hz through a C14 plug, and UL derating caps continuous draw at 12 A on a 15 A branch.
How can I confirm the PDU is metering correctly once it’s racked?
The front LCD shows real-time amperes, input voltage, kilowatts and the assigned IP address; SNMP or the CyberPower Management Console can poll the same values remotely.
Does the package include C13-to-C14 cords for my servers or must I order them separately?
Only the PDU with its attached 10 ft C14 input cord is supplied; eight C13-to-C14 jumper cords for the outlets are not included.
También en este pasillo
Los clientes también compararon
Mismo estante, mismo pago — ocho criptomonedas y un tipo de cambio fijado 30 minutos.
Thermal Grizzly TG-MP8-120-20-30-1R Minus Pad 8 chipset cooling 120x20x3.0mm
DOCTOR METAL 3x 120mm case fan pack white with controller
- Case Fan
- Case
DOCTOR METAL 120 mm case fan 3-pack with controller
- Case Fan
- Case