We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

CyberPower

CyberPower PDU15MHVIEC8FNET PDU 1U 15A 8×C13 C14 10ft

SKU CH-15WJ-GWZBE MPN PDU15MHVIEC8FNET

Monitored 1U rack PDU distributes 200-240V power to eight C13 outlets from a single C14 input with SNMP remote management and LCD metering

  • TypeMonitored
  • Rack Size1U
  • StyleRackmount, Vertical Rackmount, Under-Counter
  • Remote Management ProtocolTCP/IP, UDP, DHCP, SNMP, HTTP
  • CertificationsUL60950_1 , CSA C22.2, FCC Class A
  • ROHSYes
  • Monitored PDU with SNMP, HTTP and DHCP for remote power management
  • Eight IEC-320 C13 outlets fed from one C14 inlet simplify rack wiring
  • 1U rackmount, vertical or under-counter styles fit diverse cabinet layouts
  • 15 A input with 12 A derated protection guards connected equipment
  • LCD shows real-time amps, volts, kilowatts and IP address at a glance

Monitored PDU for rack environments

The CyberPower PDU15MHVIEC8FNET is a 1U monitored power distribution unit built for datacenters and electrically demanding installations. It accepts 200-240V input through an IEC-320 C14 plug with a 10 ft cord and delivers the same voltage range to eight IEC-320 C13 outlets. Remote management runs over TCP/IP, UDP, DHCP, SNMP and HTTP via an RJ45 Ethernet port.

15A maximum with 12A derated headroom

The unit carries a 15A maximum input current that is regulatory derated to 12A for UL and 10A for CE, giving clear headroom limits for continuous loads. Overload protection trips at the 15A rating while the derated figures define the practical continuous capacity. An LCD shows real-time current, voltage, power consumption and the IP address for quick local verification.

SNMP and HTTP over Ethernet only

Network monitoring and outlet control rely exclusively on the RJ45 Ethernet connection using SNMP, HTTP, TCP/IP, UDP and DHCP; no other remote interfaces are present. The metal chassis operates from 0 to 45 °C, up to 95 % relative humidity and at elevations up to 4500 m. Certifications include UL 60950-1, CSA C22.2 and FCC Class A with RoHS compliance.

Highlights

  • Monitored PDU with SNMP, HTTP and DHCP for remote power management
  • Eight IEC-320 C13 outlets fed from one C14 inlet simplify rack wiring
  • 1U rackmount, vertical or under-counter styles fit diverse cabinet layouts
  • 15 A input with 12 A derated protection guards connected equipment
  • LCD shows real-time amps, volts, kilowatts and IP address at a glance

Specifications

BrandCyberPower
ModelPDU15MHVIEC8FNET
TypeMonitored
Rack Size1U
StyleRackmount, Vertical Rackmount, Under-Counter
Remote Management ProtocolTCP/IP, UDP, DHCP, SNMP, HTTP
CertificationsUL60950_1 , CSA C22.2, FCC Class A
ROHSYes
Input Voltage200 - 240V
Input Frequency50/60 Hz
Maximum Input Current15A
Regulatory Derated Input Current12A
Input Connector(s)IEC-320 C14
Cord Length10 ft
Output Voltage200V - 240V
Output Connector(s)8 x IEC-320 C13
Overload Protection15A (Derated 12A-UL/10A-CE)
Operating Environment0 - 45 °C
Operating Relative Humidity0 - 95%
Operating Elevation0 - 4500 m
Storage Temperature-15 - 45 °C
Storage Elevation0 - 15000 m
FeaturesMonitored PDU with SNMP Network interface
Digital Display (Load, Voltage, KW, and IP Address)
8 IEC-320 C13 Receptacles (8 Front)
Single Phase 200-240V AC - 50/60Hz / 15-amp electrical capacity
IEC-320 C14 Plug with 10-ft. power cord
Automatic events notification via Email and SNMP Trap
User Upgradeable Firmware
1U rack mount
Rugged, industrial-grade metal housing
Dimensions17.05" x 1.75" x 4.41" (H x W x D)
Weight3.53 lbs.
Shipping weight3.36 kg
Package size498 × 251 × 61 mm

Questions about this item

Will the C14 inlet and 12 A derated limit work with my existing 208 V rack circuit?

Yes — the unit accepts 200–240 V at 50/60 Hz through a C14 plug, and UL derating caps continuous draw at 12 A on a 15 A branch.

How can I confirm the PDU is metering correctly once it’s racked?

The front LCD shows real-time amperes, input voltage, kilowatts and the assigned IP address; SNMP or the CyberPower Management Console can poll the same values remotely.

Does the package include C13-to-C14 cords for my servers or must I order them separately?

Only the PDU with its attached 10 ft C14 input cord is supplied; eight C13-to-C14 jumper cords for the outlets are not included.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.