CyberPower
CyberPower PDU24007 Metered ATS PDU 2U 19 Outlets 30A 10ft
A 2U rackmount PDU with 19 outlets, automatic transfer switching and a 10 ft cord for 30 A, 200–240 VAC power distribution
- TypeMetered
- Rack Size2U
- StyleRackmount
- Input Voltage240 – 200 VAC
- Input Frequency50 Hz – 60 Hz
- Maximum Input Current30A
- Automatic transfer switch keeps equipment running during source failure
- Metered LCD display shows real-time load on 30A input
- Nineteen mixed outlets support diverse rack devices from one unit
- Two 20A breakers protect circuits from overload damage
- Ten-foot cord and 2U metal chassis fit standard rack layouts
Rackmount Metered ATS PDU 2U
The CyberPower PDU24007 is a 2U rackmount power distribution unit built for server rooms and network closets that require redundant power paths. It accepts 200 to 240 VAC at 50 or 60 Hz and supports a maximum input current of 30A. The unit is suited for administrators who need monitored power delivery with automatic source switching.
19 Outlets with Automatic Transfer Switch
Nineteen output connectors include sixteen IEC-320 C13, two IEC-320 C19 and one NEMA L6-30R receptacles. The integrated automatic transfer switch moves the load to a secondary source without interruption when the primary feed fails. Dual 20A circuit breakers provide overload protection for each bank. A selectable colour LCD displays real-time voltage, current and power data.
Metal Housing 10ft Cord Industrial Ratings
Durable metal housing protects internal components from impact and abrasion in challenging industrial environments. The 10 ft (3.0 m) straight input cord reaches floor-mounted or overhead feeds without extension cables. Operating temperature spans 32 to 113 °F (0 to 45 °C) with humidity up to 95 % non-condensing and elevation up to 13123 ft (4000 m). The 15.4 lb chassis fits standard 19-inch racks at 17.05 x 3.5 x 8.45 in. Builders needing higher outlet counts or different plug types must look elsewhere.
Puntos fuertes
- Automatic transfer switch keeps equipment running during source failure
- Metered LCD display shows real-time load on 30A input
- Nineteen mixed outlets support diverse rack devices from one unit
- Two 20A breakers protect circuits from overload damage
- Ten-foot cord and 2U metal chassis fit standard rack layouts
Especificaciones
| Brand | CyberPower |
|---|---|
| Series | Metered ATS PDU |
| Model | PDU24007 |
| Part Number | PDU24007 |
| Type | Metered |
| Rack Size | 2U |
| Style | Rackmount |
| Input Voltage | 240 – 200 VAC |
| Input Frequency | 50 Hz – 60 Hz |
| Maximum Input Current | 30A |
| Input Connector(s) | Straight |
| Cord Length | 10 ft (3.0 m) |
| Output Voltage | 240 – 200 VAC |
| Output Watts (VA) | 240 – 200 VAC |
| Output Connector(s) | 19 |
| Overload Protection | 20A x 2 |
| Operating Environment | 32 – 113 °F (0 – 45 °C) |
| Operating Relative Humidity | 0 – 95 % (non-condensing) |
| Operating Elevation | 0 – 13123 ft (0 – 4000 m) |
| Storage Temperature | 5 – 131 °F (-15 – 55 °C) |
| Dimensions | 17.05 x 3.5 x 8.45 (in) |
| Weight | 15.4 lb |
| Peso de envío | 8.80 kg |
| Dimensiones del paquete | 550 × 398 × 185 mm |
Preguntas sobre este artículo
Will the 20 A overload-protection breakers need periodic replacement?
The unit uses two 20 A breakers for overload protection; they are resettable devices and only require replacement if a breaker fails to hold after a trip.
What limits continuous 30 A operation first?
The 20 A per-bank breakers will trip before the 30 A input rating is reached, so each bank caps sustained draw at 20 A.
How much heat does the PDU add when running all day?
Operating temperature range is 32 – 113 °F (0 – 45 °C); the metal housing passively dissipates heat without fans, so added heat is minimal.