我們接受加密貨幣付款 — 讓您持有的幣種也能買到真正的硬體設備。以加密貨幣付款,直接購入真正的硬體設備。 全球訂單滿 US$399,即享免費保險運送。簡約外箱,不印任何品牌標誌,從德國出貨。訂單滿 US$399,即享免費保險運送。 結帳一開始,您的匯率即鎖定 30 分鐘。匯率鎖定 30 分鐘。 每件商品皆原廠密封、序號經過核對,並享有 24 個月保固。原廠密封,保固 24 個月。

追蹤清單 登入

CyberPower

CyberPower PDU24007 Metered ATS PDU 2U 19 Outlets 30A 10ft

SKU CH-RX0F-EX7EQ MPN PDU24007

A 2U rackmount PDU with 19 outlets, automatic transfer switching and a 10 ft cord for 30 A, 200–240 VAC power distribution

  • TypeMetered
  • Rack Size2U
  • StyleRackmount
  • Input Voltage240 – 200 VAC
  • Input Frequency50 Hz – 60 Hz
  • Maximum Input Current30A
  • Automatic transfer switch keeps equipment running during source failure
  • Metered LCD display shows real-time load on 30A input
  • Nineteen mixed outlets support diverse rack devices from one unit
  • Two 20A breakers protect circuits from overload damage
  • Ten-foot cord and 2U metal chassis fit standard rack layouts

Rackmount Metered ATS PDU 2U

The CyberPower PDU24007 is a 2U rackmount power distribution unit built for server rooms and network closets that require redundant power paths. It accepts 200 to 240 VAC at 50 or 60 Hz and supports a maximum input current of 30A. The unit is suited for administrators who need monitored power delivery with automatic source switching.

19 Outlets with Automatic Transfer Switch

Nineteen output connectors include sixteen IEC-320 C13, two IEC-320 C19 and one NEMA L6-30R receptacles. The integrated automatic transfer switch moves the load to a secondary source without interruption when the primary feed fails. Dual 20A circuit breakers provide overload protection for each bank. A selectable colour LCD displays real-time voltage, current and power data.

Metal Housing 10ft Cord Industrial Ratings

Durable metal housing protects internal components from impact and abrasion in challenging industrial environments. The 10 ft (3.0 m) straight input cord reaches floor-mounted or overhead feeds without extension cables. Operating temperature spans 32 to 113 °F (0 to 45 °C) with humidity up to 95 % non-condensing and elevation up to 13123 ft (4000 m). The 15.4 lb chassis fits standard 19-inch racks at 17.05 x 3.5 x 8.45 in. Builders needing higher outlet counts or different plug types must look elsewhere.

商品特色

  • Automatic transfer switch keeps equipment running during source failure
  • Metered LCD display shows real-time load on 30A input
  • Nineteen mixed outlets support diverse rack devices from one unit
  • Two 20A breakers protect circuits from overload damage
  • Ten-foot cord and 2U metal chassis fit standard rack layouts

商品規格

BrandCyberPower
SeriesMetered ATS PDU
ModelPDU24007
Part NumberPDU24007
TypeMetered
Rack Size2U
StyleRackmount
Input Voltage240 – 200 VAC
Input Frequency50 Hz – 60 Hz
Maximum Input Current30A
Input Connector(s)Straight
Cord Length10 ft (3.0 m)
Output Voltage240 – 200 VAC
Output Watts (VA)240 – 200 VAC
Output Connector(s)19
Overload Protection20A x 2
Operating Environment32 – 113 °F (0 – 45 °C)
Operating Relative Humidity0 – 95 % (non-condensing)
Operating Elevation0 – 13123 ft (0 – 4000 m)
Storage Temperature5 – 131 °F (-15 – 55 °C)
Dimensions17.05 x 3.5 x 8.45 (in)
Weight15.4 lb
出貨重量8.80 kg
包裝尺寸550 × 398 × 185 mm

商品問答

Will the 20 A overload-protection breakers need periodic replacement?

The unit uses two 20 A breakers for overload protection; they are resettable devices and only require replacement if a breaker fails to hold after a trip.

What limits continuous 30 A operation first?

The 20 A per-bank breakers will trip before the 30 A input rating is reached, so each bank caps sustained draw at 20 A.

How much heat does the PDU add when running all day?

Operating temperature range is 32 – 113 °F (0 – 45 °C); the metal housing passively dissipates heat without fans, so added heat is minimal.

同類商品

顧客也比較過

同一分類,同一套結帳流程 — 支援八種加密貨幣,匯率鎖定 30 分鐘。