PULS Power
PULS Power ML Series 10-12VDC 30W DIN Rail Power Supply
DIN-rail switching supply delivers 10-12 VDC at 30 W from 100-240 VAC input
- TypeATX
- Wide 100-240 VAC input works worldwide
- Compact 45 mm DIN-rail width saves cabinet space
- 30 W at 10-12 VDC delivers 3.0 A for control circuits
- 10 °C to 70 °C range suits harsh environments
- cULus, cRUus, Class I Div 2, CE, RoHS, NEC Class 2 compliance
ML Series 30 W DIN Rail Supply
This PULS Power ML Series unit is a compact DIN rail power supply that converts 100 to 240 VAC input into a 10 to 12 VDC output rated at 30 W. It mounts on standard DIN rail inside a plastic enclosure measuring 75 mm high, 45 mm wide and 91 mm deep. A status LED provides visual confirmation of operation. The supply meets cUL, cRU, Class I Division 2, CE, RoHS and NEC Class 2 standards.
Suited for low-power control cabinets
The 3 A output suits panels powering sensors, small PLCs or relay coils where space is limited and a wide AC input range is required. The operating range of -10 to 70 °C covers unheated enclosures. Builders who need more than 30 W, higher output voltage or redundant inputs should look at larger units. Applications requiring IP-rated protection beyond IP20 also need a different enclosure.
30 W at 10-12 VDC decides fit
The single figure that determines compatibility is the 30 W continuous rating at 10 to 12 VDC. If the connected load draws more than 3 A the supply will not sustain operation. Verify the total wattage of every device on the rail before specifying this model.
주요 특징
- Wide 100-240 VAC input works worldwide
- Compact 45 mm DIN-rail width saves cabinet space
- 30 W at 10-12 VDC delivers 3.0 A for control circuits
- 10 °C to 70 °C range suits harsh environments
- cULus, cRUus, Class I Div 2, CE, RoHS, NEC Class 2 compliance
사양
| Type | ATX |
|---|
이 상품에 대한 질문
Will the electrolytic capacitors inside the 30 W ML Series unit need scheduled replacement?
The supply is rated for long lifetime at up to 70 °C ambient; no user-serviceable capacitor replacement interval is published.
What limits continuous output when the supply runs at 3.0 A on a DIN rail?
The 30 W rating and convection-cooled plastic case mean thermal dissipation is the first constraint under sustained full load.
How much heat and noise does the ML Series produce when powering a 12 V load all day?
Silent convection cooling with no fan; the plastic enclosure reaches a temperature determined by the 30 W loss and 75 × 45 × 91 mm footprint.
이 진열대의 다른 상품