APC
APC AP4430 Rack ATS 200/208V 20A L6-20 8xC13 1xC19 1U PDU
Rack-mount automatic transfer switch delivering redundant 200/208 V power to single-corded gear via eight C13 and one C19 outlets
- TypeBasic
- Rack Size1U
- CertificationsEN 55022 Class A, FCC Part 15 Class A
- Input Voltage200V, 208V
- Input Frequency50/60 Hz
- Maximum Input Current20A
- Redundant dual-input power protects single-corded equipment from source failure
- Automatic transfer switches between sources without interrupting critical loads
- Eight C13 and one C19 outlets deliver 200/208V power to rack devices
- 1U rack-mount form factor preserves space in dense server cabinets
- Remote management via Web, SNMP or Telnet enables off-site monitoring
Rack ATS 1U Dual Input
The APC AP4430 is a rack-mount automatic transfer switch that provides redundant power to single-corded equipment. It accepts two 200V or 208V AC sources and switches seamlessly between them without interrupting connected loads. The unit occupies 1U of rack space and includes an 8.0-foot input cord with a NEMA L6-20P plug.
20A Input 16A Derated Output
Maximum input current is rated at 20A while the regulatory derated input current is 16A, defining the continuous load ceiling. Nine output receptacles are provided: eight IEC 320 C13 outlets and one IEC 320 C19 outlet, all delivering battery-backed power. The switch operates at 50 or 60 Hz and supports input voltages of 200V and 208V.
Network Management 45°C Operation
Built-in network connectivity enables remote management through Web, SNMP, or Telnet interfaces for monitoring and control. The operating temperature range spans -5 to 45 degrees Celsius with relative humidity from 5 to 95 percent non-condensing. Certifications include EN 55022 Class A and FCC Part 15 Class A for electromagnetic compatibility.
Highlights
- Redundant dual-input power protects single-corded equipment from source failure
- Automatic transfer switches between sources without interrupting critical loads
- Eight C13 and one C19 outlets deliver 200/208V power to rack devices
- 1U rack-mount form factor preserves space in dense server cabinets
- Remote management via Web, SNMP or Telnet enables off-site monitoring
Specifications
| Brand | APC |
|---|---|
| Model | AP4430 |
| Type | Basic |
| Rack Size | 1U |
| Certifications | EN 55022 Class A, FCC Part 15 Class A |
| Input Voltage | 200V, 208V |
| Input Frequency | 50/60 Hz |
| Maximum Input Current | 20A |
| Regulatory Derated Input Current | 16A |
| Input Connector(s) | NEMA L6-20P |
| Cord Length | 8.0 Feet |
| Output Voltage | 200V, 208V |
| Output Connector(s) | 1 x IEC 320 C19 (Battery Backup) 8 x IEC 320 C13 (Battery Backup) |
| Operating Environment | -5 - 45 Degree Celcius |
| Operating Relative Humidity | 5 - 95% |
| Operating Elevation | 0 - 3000 m |
| Storage Temperature | -25 - 65 Degree Celcius |
| Storage Relative Humidity | 5 - 95% |
| Storage Elevation | 0 - 15000 m |
| Features | Rack-Mountable Occupys only 1U of valuable rack space. Puts the power where it is needed most - in the rack near the equipment. Dual Input Power Sources Supplies redundant AC power to connected equipment. Two AC lines power the unit and if the primary AC power fails, the unit will automatically switch to the alternative power source. Information Displays Indicates the status of the AC sources powering the units, as well as indicates which source is set as the primary source and which source is currently supplying power to the load. This provides a visual depiction of the power flow f |
| Dimensions | 1.72" x 17.00" x 9.30" |
| Weight | 10.65 lbs. |
| Shipping weight | 5.90 kg |
| Package size | 508 × 312 × 120 mm |
Questions about this item
Will the AP4430 draw 16 A from my existing 200 V L6-20 circuit without tripping?
The regulatory derated input is 16 A at 200 V or 208 V, so a 20 A L6-20 feed stays within its continuous rating.
How can I confirm the automatic transfer is functioning after I rack-mount the AP4430?
Connect to the built-in network interface and watch the Web or SNMP dashboard show primary and secondary source status during a simulated outage.
Does the AP4430 ship with the 8.0 ft L6-20 input cord and all mounting hardware?
Yes, the 8.0 ft NEMA L6-20P cord is attached; rack-mount brackets are included, while IEC C13 and C19 output cables are sold separately.