We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
APC
A metered 0U vertical rack PDU with ten NEMA 5-15R outlets, 15 A input via NEMA 5-15P, and a 9.8-foot cord for real-time power monitoring
This metered rack PDU delivers 100-120V input at 15A through a NEMA 5-15P plug rated at 1.4 kW. It provides ten NEMA 5-15R outlets for powering servers and network gear in a vertical 0U form factor. The unit includes active metering with user-defined alarm thresholds for real-time local and remote overload alerts. Data center managers gain power utilization data for load balancing and capacity planning decisions.
The 0U vertical mounting design installs alongside equipment without consuming horizontal rack units. A 9.8 foot cord connects the NEMA 5-15P input to facility power. Ten 5-15R receptacles accept standard North American equipment plugs. The package includes rack mounting brackets for secure installation. A temperature and humidity sensor port supports environmental monitoring when paired with compatible sensors.
The shipment includes a serial configuration cable for initial setup and direct console access. Installation and safety guides provide physical mounting and electrical safety instructions. Secure Web, SNMP and Telnet interfaces enable remote configuration and monitoring. Compatibility with APC InfraStruxure Central, Operations, Capacity and Energy Efficiency platforms allows centralized management across multiple PDUs. Locking IEC receptacles and ultra low profile circuit breakers are noted as product features.
| Type | AT |
|---|
The unit includes an ultra low profile circuit breaker rated at 15A that will open the circuit if the total draw exceeds that limit.
The metering electronics draw only a few watts so the PDU itself contributes negligible heat; almost all thermal load comes from the connected equipment.
The 9.8‑foot cord terminates in a NEMA 5‑15P plug that requires a matching 120V 15A receptacle.
Also in this aisle
Same shelf, same checkout — eight coins and a 30-minute rate lock.
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
Pick the language the site speaks to you in.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?