CyberPower CP850AVRLCD UPS 850VA/510W 120V 9 Outlets Mini-Tower
- 90Vac - 140Vac
- 60Hz +/- 3 Hz
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
CyberPower
Battery backup delivers 825 VA and 450 W through eight NEMA 5-15R outlets with an LCD status panel and USB management
The CyberPower CP825AVRLCD is a 825VA/450W uninterruptible power supply built for desktop computers and networking gear that need short-term ride-through during outages. It accepts a 120V 60Hz feed through a NEMA 5-15P plug and delivers regulated 120V output within 5 percent. Eight NEMA 5-15R receptacles provide both battery-backed and surge-only connections. The sealed lead-acid battery is user-replaceable with the RB1280A cartridge.
A multi-function LCD panel shows real-time voltage, load level, battery capacity and runtime estimates so you can react before power runs out. The HID USB port links to the included PowerPanel Personal Edition software for automated shutdown and event logging. Built-in RJ-45 and RJ-11 pass-through jacks protect Ethernet and phone lines from surges that travel on data cables. UL1778 and cUL 107.1 listings confirm the safety construction, while RoHS compliance documents the material restrictions.
At half load the unit supplies power for roughly 13 minutes; at full load the window shrinks to about 2 minutes. Recharging the battery from depletion takes approximately 8 hours, so the UPS is intended for brief interruptions rather than extended operation. The 450-watt ceiling limits the total connected equipment, and the single USB interface does not support network management cards. Buyers needing longer runtime or higher wattage should consider larger-capacity models.
| Brand | CyberPower |
|---|---|
| Model | CP825AVRLCD |
| International Version | 120V |
| Input Frequency | 60 Hz +/- 3 Hz |
| Input Connection | NEMA 5-15P |
| VA Rating | 825 VA |
| Watts | 450 Watts |
| Output Voltage | 120Vac +/- 5% |
| Output Frequency | 60Hz +/- 1% |
| Outlets | 8 |
| Outlet Type | NEMA 5-15R |
| Battery Type | Sealed Lead Acid |
| Battery Run Time | 8 minutes runtime at Half Load 2 minutes runtime at Full Load |
| Battery Recharge Time | 8 Hour(s) |
| Battery Replaceable | RB1280A |
| Alarms | On Battery / Low Battery / Overload |
| Interface Port | USB |
| Management Software | PowerPanel Personal Edition |
| Approvals | UL1778, cUL 107.1, FCC DOC Class B, RoHS Compliant |
| Data Line Protection | RJ-45 Ethernet / RJ-11 Phone protection: 1-In, 1-Out (Combo) |
| Surge Energy Rating | 1030 Joules |
| Protection | Internal Circuitry Limiting Circuit Breaker |
| Features | The Intelligent LCD Series CP825AVRLCD UPS, designed for mid- to high-end computer systems, is the only UPS in its class to feature the combined power of AVR line conditioning, multifunction LCD readout, compact footprint, and "Green UPS" cost-reducing technology. Automatic Voltage Regulation (AVR) - Incoming AC power is electronically regulated for dips and spikes. AVR takes this irregular AC power and converts it into a consistent Sinewave, so sensitive electronic equipment can achieve its optimal performance. Ultra-Quiet UPS - The combination of an advanced ventilation design, hig |
| Dimensions | 11.50" x 6.50" x 3.50" |
| Weight | 14.00 lbs. |
| Package Contents | UPS System User Manual USB A+B Type Cable PowerPanel Personal Edition Software CD Telephone Cable Coaxial Cable Warranty Registration Card |
| Shipping weight | 7.12 kg |
| Package size | 371 × 251 × 132 mm |
Other versions of this model
Same family, different memory, cooler or clock — compare before you commit.
The sealed lead-acid RB1280A battery is hot-swappable and designed for user replacement; typical service life is three to five years depending on discharge cycles and ambient temperature.
At full load the unit provides 2 minutes of battery backup; at half load it extends to 13 minutes, so plan shutdown scripts accordingly.
Under normal line power the fan stays off; it activates only on battery or overload, producing low audible noise and minimal extra heat in the rack or desk space.
Also in this aisle
Same shelf, same checkout — eight coins and a 30-minute rate lock.
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
Pick the language the site speaks to you in.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?