We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
MINUTEMAN
Online UPS delivers 1500VA and 1350W with lithium batteries in a 2U rack or tower form factor
Model END1500RT2U-LNC
The Minuteman END1500RT2U-LNC is a new online UPS rated at 1500VA and 1350W with a 0.9 power factor. It uses lithium batteries and fits a 2U rack or tower footprint, delivering a true sine-wave output at 120V.
This unit suits operators who need continuous double-conversion protection for servers or network gear in a compact rack space. Buyers who require a different input voltage range or a form factor other than 2U rack/tower should look at other models.
The online topology with lithium batteries that recharge to full capacity in 2 hours is the specification that determines fit. It provides zero transfer time and a longer service life than lead-acid alternatives in the same 2U envelope.
| Brand | MINUTEMAN |
|---|---|
| Model | END1500RT2U-LNC |
| International Version | 120V |
| Input Voltage Range | 55VAC-160VAC +/- 5 % ( Load Dependent) |
| Input Frequency | 40Hz ~ 70 Hz |
| VA Rating | 1500VA |
| Watts | 1350W |
| Output Voltage | 100/110/115/120/125/127 VAC |
| Output Frequency | 47 ~ 53 Hz or 57 ~ 63 Hz |
| Battery Type | LIFE-247500 |
| Battery Recharge Time | 2 hours recover to 100% capacity @ 4A charging current |
| Humidity | 20-95 % RH @ 0- 40°C (non-condensing) |
| Dimensions | 16.1” x 17.2” x 3.5” |
| Weight | 25.6 lbs. |
| Shipping weight | 11.25 kg |
| Package size | 437 × 409 × 86 mm |
Other versions of this model
Same family, different memory, cooler or clock — compare before you commit.
The lithium chemistry is rated for far more cycles than lead-acid, typically lasting 8-10 years before capacity drops to the point where a pack swap is needed.
Thermal protection will trip if the internal temperature exceeds the 40 °C operating ceiling, so sustained full-load runtime depends on keeping ambient air below that threshold.
Online double-conversion topology means the inverter runs constantly, generating steady heat that requires front-to-rear airflow; fan speed ramps with load, so a 1350 W load produces audible but not disruptive airflow noise.
Also in this aisle
Same shelf, same checkout — eight coins and a 30-minute rate lock.
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
Pick the language the site speaks to you in.
No language matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?