Supermicro
Supermicro SYS-6018U-TR4T+ 1U rack server 2x Xeon E5-2660 v4 2.0GHz 14-core 768GB DDR4 4x 3.5" bays
1U rack server with dual 14-core Xeon E5-2660 v4 CPUs, 768GB DDR4 ECC memory, MegaRAID 9361-8i controller, four 3.5" hot-plug bays, quad 10GBase-T ports and IPMI 2.0 management
- Rack Height1U
- Redundant Hot-swap PowerYes
- CPU TypeIntel Xeon
- CPU Speed2.00 GHz
- CPU SocketLGA 2011-3
- Number of CPU Cores14-Core Processor
- Dual Xeon E5-2660 v4 14-core processors run at 2.0 GHz with 3.2 GHz turbo
- 768 GB DDR4 2400 MHz ECC memory fills 24 slots for memory-intensive workloads
- MegaRAID 9361-8i controller supports RAID 0, 1, 5, 6, 10, 50, 60 with 1 GB cache and battery backup
- Quad 10GBase-T ports via Intel X540 controller provide high-speed network connectivity
- Dual 750 W platinum power supplies with hot-swap redundancy ensure continuous operation
Dual-socket 1U server for memory-heavy workloads
The Supermicro SYS-6018U-TR4T+ is a 1U rackmount system with two Intel Xeon E5-2660 v4 processors. Each CPU runs at 2.0 GHz with 14 cores and a 3.2 GHz turbo frequency. The box ships with 768 GB of DDR4 2400 MHz registered ECC memory across 24 DIMM slots.
Fits virtualisation and HPC clusters.
This server suits teams that need dense CPU throughput and quad 10GBase-T networking in a single rack unit. The LSI MegaRAID 9361-8i controller manages up to four 3.5-inch hot-swap SATA or SAS drives in RAID 0, 1, 5, 6, 10, 50 or 60. Buyers who need GPU acceleration or more than four drive bays should look elsewhere.
768 GB DDR4 ECC decides capacity ceiling
Installed memory is 768 GB (24 × 32 GB DDR4 2400 MHz registered ECC). The platform supports up to 1.5 TB, so the current configuration leaves room to grow without replacing modules. Memory size is the single specification that determines whether this chassis meets the dataset footprint.
Highlights
- Dual Xeon E5-2660 v4 14-core processors run at 2.0 GHz with 3.2 GHz turbo
- 768 GB DDR4 2400 MHz ECC memory fills 24 slots for memory-intensive workloads
- MegaRAID 9361-8i controller supports RAID 0, 1, 5, 6, 10, 50, 60 with 1 GB cache and battery backup
- Quad 10GBase-T ports via Intel X540 controller provide high-speed network connectivity
- Dual 750 W platinum power supplies with hot-swap redundancy ensure continuous operation
Specifications
| Brand | SUPERMICRO |
|---|---|
| Series | CSE-819U + X10DRU-i+ |
| Model | SYS-6018U-TR4T+ |
| Rack Height | 1U |
| Redundant Hot-swap Power | Yes |
| CPU Type | Intel Xeon |
| CPU Speed | 2.00 GHz |
| CPU Socket | LGA 2011-3 |
| Number of CPU Cores | 14-Core Processor |
| # of Processors Installed | E5-2660 V4 |
| Installed Memory Size | 768GB |
| Storage Controller | LSI MegaRAID 9361-8i Controller |
| HDD Interface | SATA/SAS |
| SSD (Installed) | No |
| Raid Level | RAID 0/1/5/6/10/50/60 |
| GPU Type | Matrox G200 |
| Video Memory | 8MB |
| Ethernet Controller | Supermicro AOC-UR-i4XT - Intel X540 - 4x RJ45 10GBase-T Ports |
| Management Port | RJ 45 |
| Features | 4 x 3.5" SATA/SAS Hot-Plug Drive Bays |
Questions about this item
How are the two Xeon E5-2660 v4 processors and the 24 DIMM slots installed, and which step is most often missed?
Seat both CPUs into the LGA 2011-3 sockets, apply thermal paste, attach the heatsinks, then populate all 24 slots with DDR4 2400 MHz registered ECC modules; the step most often missed is enabling the memory training option in the BIOS before first boot.
Which components will need replacement first during the server's service life?
The two 750 W Platinum hot-swap power supplies and the MegaRAID 9361-8i controller's backup battery are the first items that typically require replacement under continuous operation.
What thermal or power limit appears first when the system runs sustained heavy workloads?
The 1U chassis airflow ceiling is reached before the dual 750 W supplies hit their maximum, so CPU turbo drops to base 2.0 GHz once inlet temperatures climb.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.



