MINUTEMAN
MINUTEMAN EC3000RTXL2UNC 3000VA 2700W 120V Online UPS
Online UPS delivers 3000VA 2700W pure sine output with six controllable NEMA 5-15/20R outlets and extended runtime
- International Version120V
- Input Voltage Range0-160VAC
- Input Frequency50/60Hz, +/-6Hz, Auto-sensing
- Input ConnectionNEMA L5-30P
- VA Rating3000VA
- Watts2700W
Model EC3000RTXL2UNC
- EC3000RTXL2UNC
- EC1000LCD
- EC1000LCD-NC
- EC1000RTXL2U
- EC1000RTXL2UNC
- EC1500LCD
- EC1500LCD-NC
- EC1500RT2U
- EC1500RT2UNC
- EC1500RTXL2U
- EC1500RTXL2UNC
- EC2000LCD
Ver as outras 7 configurações
As versões riscadas existem, mas não estão disponíveis aqui.
- Online double-conversion topology delivers clean 120 V power
- 3000 VA and 2700 W capacity supports heavy server loads
- Six 5-15/20R plus one L5-30R outlets offer flexible connections
- Replaceable sealed lead-acid battery module BM0071 extends service life
- cTUVus, FCC Class A, CE, Energy Star 2.0 and RoHS2 certified
High-capacity online UPS for critical 120V loads
The Minuteman EC3000RTXL2UNC is a 3000VA, 2700W online UPS that delivers continuous true sine-wave power to servers, networking gear and sensitive electronics. Its double-conversion topology isolates connected equipment from voltage fluctuations, frequency drift and harmonic distortion on the utility line. The unit operates on 120V input and output with a 0.9 power factor.
Rack or tower form factor with NEMA L5-30P input
The chassis fits a standard 2U rack space or stands as a tower, offering seven outlets: six NEMA 5-15/20R receptacles and one NEMA L5-30R for high-draw devices. A NEMA L5-30P plug connects to a 30A branch circuit. Six of the outlets are individually controllable, allowing sequenced shutdowns or selective load shedding during extended outages. USB communication supports monitoring software integration.
User-replaceable battery module BM0071
Sealed lead-acid cells provide 10 minutes of runtime at half load and 3 minutes at full load. The BM0071 cartridge can be swapped without tools or downtime, extending the service life of the UPS beyond the battery cycle limit. Energy Star 2.0 and DoE 10 CFR Part 430 compliance reflect efficient operation, while cTUVus, FCC Class A, CE and RoHS2 marks confirm regulatory adherence for commercial deployment.
Pontos fortes
- Online double-conversion topology delivers clean 120 V power
- 3000 VA and 2700 W capacity supports heavy server loads
- Six 5-15/20R plus one L5-30R outlets offer flexible connections
- Replaceable sealed lead-acid battery module BM0071 extends service life
- cTUVus, FCC Class A, CE, Energy Star 2.0 and RoHS2 certified
Especificações
| Brand | MINUTEMAN |
|---|---|
| Series | ENCOMPASS RTXL |
| Model | EC3000RTXL2UNC |
| International Version | 120V |
| Input Voltage Range | 0-160VAC |
| Input Frequency | 50/60Hz, +/-6Hz, Auto-sensing |
| Input Connection | NEMA L5-30P |
| VA Rating | 3000VA |
| Watts | 2700W |
| Output Voltage | 120V |
| Output Frequency | 50/60Hz, +/-0.2Hz (unless synchronized to utility) |
| Outlets | 7 |
| Outlet Type | (6) NEMA 5-15/20R / (1) L5-30R |
| Battery Type | Sealed Lead Acid |
| Battery Run Time | Half Load: 10 min Full Load: 3 min |
| Battery Replaceable | BM0071 |
| Approvals | cTUVus (Conforms to UL1778 5th Edition & CSA 22.2 no. 107.3-14 /R: 2014), FCC Class A, CE certified, Energy Star 2.0, DoE 10 CFR Part 430, RoHS2 (EU Directive 2011/65/EU) |
| Rackmountable | Yes |
| Temperature | 0° to 40°C (+32° to +104°F) |
| Humidity | 10% to 90% non-condensing |
| Dimensions | 23.7" x 18.9" x 3.5" |
| Weight | 65.7 lbs. |
| Peso de envio | 30.03 kg |
| Dimensões da embalagem | 602 × 480 × 89 mm |
Outras versões deste modelo
Mais 5 nesta gama
Mesma família, memória, ventoinha ou frequência diferentes — compare antes de decidir.
MINUTEMAN EC3000RT2U UPS 3000VA 2700W 2U Rack/Tower 120V 7 Outlets
- 120V
- 0-160VAC
MINUTEMAN EC3000LCD-NC Encompass 3000VA 2700W Tower UPS
- 120V
- 0-160VAC
MINUTEMAN EC2000RTXL2UNC UPS 2000VA 1800W 120V 6x NEMA 5-15/20R
- 120V
- 0-160VAC
MINUTEMAN ENCOMPASS EC3000RT2UNC 3000VA 2700W 2U Rack/Tower UPS
- 120V
- 0-160VAC
Perguntas sobre este artigo
How long will the battery last when the UPS is running at full 2700 W load?
The internal sealed lead-acid pack provides 3 minutes of runtime at full 2700 W load and 10 minutes at half load.
What is the operating temperature range and noise consideration for continuous rack use?
The unit is rated for 0° to 40°C (32° to 104°F) with 10 % to 90 % non-condensing humidity; fan noise will be present during continuous online operation.
Which input plug and outlet types are already on the unit so I know what cables to prepare?
It ships with a NEMA L5-30P input cord, six NEMA 5-15/20R outlets and one L5-30R outlet.
Também nesta secção
Os clientes também compararam
Mesma prateleira, mesma finalização da compra — oito moedas e uma taxa bloqueada durante 30 minutos.
Thermal Grizzly TG-MP8-120-20-30-1R Minus Pad 8 chipset cooling 120x20x3.0mm
DOCTOR METAL 3x 120mm case fan pack white with controller
- Case Fan
- Case
DOCTOR METAL 120 mm case fan 3-pack with controller
- Case Fan
- Case