我們接受加密貨幣付款 — 讓您持有的幣種也能買到真正的硬體設備。以加密貨幣付款,直接購入真正的硬體設備。 全球訂單滿 US$399,即享免費保險運送。簡約外箱,不印任何品牌標誌,從德國出貨。訂單滿 US$399,即享免費保險運送。 結帳一開始,您的匯率即鎖定 30 分鐘。匯率鎖定 30 分鐘。 每件商品皆原廠密封、序號經過核對,並享有 24 個月保固。原廠密封,保固 24 個月。

追蹤清單 登入

DELL

DELL PowerEdge R730XD 2U rack server 12 x 3.5" E5-2650 v3 10C 2.3GHz 16GB DDR4 H730

SKU CH-TED0-2YGC1

A 2U rack server holding twelve 3.5-inch hot-plug drives, powered by a ten-core 2.3 GHz Xeon with 16 GB DDR4 and an H730 RAID controller supporting RAID 0/1/5/6/10/50/60

  • TypeRack
  • Rack Height2U
  • Redundant Hot-swap PowerYes
  • CPU TypeIntel Xeon
  • MAX Processors2
  • ChipsetIntel C610
  • Ten-core Xeon at 2.3 GHz for parallel workloads
  • 12 hot-plug 3.5" bays support up to 52 TB storage
  • H730 RAID controller handles RAID 0/1/5/6/10/50/60
  • 16 GB DDR4 installed with 24 DIMM slots for expansion
  • Dual 750 W redundant power supplies keep the server running

Dense 2U rack server for storage-heavy workloads

The Dell PowerEdge R730XD fits twelve 3.5-inch hot-plug bays into a 2U chassis, giving a maximum raw capacity of 52 TB with SAS or SATA drives. A single Xeon E5-2650 v3 provides ten cores at 2.3 GHz and twenty threads, while the Perc H730 controller supports RAID 0, 1, 5, 6, 10, 50 and 60. The system ships with 16 GB of DDR4 across twenty-four DIMM slots and includes a DVD-ROM drive.

Dual 750 W redundant supplies with hot-swap cooling

Two redundant 750 W power supplies share the load and can be swapped without shutting down. The 2U form factor uses internal airflow channels that direct cool air across the processors, memory and drive bays before exhausting it at the rear. Under typical mixed read and write activity the fans run at moderate speeds, keeping inlet temperatures within specification while acoustic output remains suitable for a standard server room.

Sustained throughput with controller-backed caching

The H730 card includes 1 GB of cache backed by a capacitor, allowing write acknowledgements to complete before data reaches the platters during extended write streams. Six PCIe 3.0 slots plus a dedicated RAID slot leave room for additional networking or acceleration cards without reducing drive count. The iDRAC8 remote-management module provides out-of-band monitoring and power control even when the host operating system is unresponsive.

商品特色

  • Ten-core Xeon at 2.3 GHz for parallel workloads
  • 12 hot-plug 3.5" bays support up to 52 TB storage
  • H730 RAID controller handles RAID 0/1/5/6/10/50/60
  • 16 GB DDR4 installed with 24 DIMM slots for expansion
  • Dual 750 W redundant power supplies keep the server running

商品規格

BrandDELL
SeriesPowerEdge
ModelPowerEdge R730XD
TypeRack
Rack Height2U
Redundant Hot-swap PowerYes
CPU TypeIntel Xeon
MAX Processors2
ChipsetIntel C610
Installed Memory Size16GB
Memory TypeDDR4
Max Memory Capacity16GB
Memory Features24 DIMM slots, 12 per processor. (4GB/8GB/16GB/32GB/64GB/128GB DDR4 up to 2400MT/s, actual memory speed dependent on the processor capability)
Number of Memory Slots24
Storage ControllerDell Perc H730 Controller
SSD (Installed)No
Raid LevelRAID 0/1/5/6/10/50/60
Max HDD Capacity52TB
Media DrivesDVD ROM
GPU TypeMatrox G200
Video Memory8MB
Remote ManagementiDRAC8 with Lifecycle Controller, iDRAC8 Express (default), iDRAC8 Enterprise (upgrade) 8GB vFlash media (upgrade), 16GB vFlash media (upgrade)
LAN Ports4 x Ports
Expansion SlotsUp to 7 x PCIe 3.0 plus dedicated PERC slot
Operating SystemNo
Compatible/Certified OSMicrosoft Windows Small Business Server 2011/2008, Microsoft Windows Server 2008 R2 SP1/SP2, Microsoft Windows HPC Server 2008 R2, Novell SUSE Linux Enterprise Server, Red Hat Enterprise Linux, Oracle Solaris
Weight70.0000LBS

其他版本

同系列還有 5 款

同系列產品,記憶體、散熱器或時脈不同 — 下單前請先比較。

商品問答

How do I install drives in the 12 x 3.5" hot-plug bays and what step is often missed?

Slide each SAS or SATA drive into a bay until the latch clicks; the step often missed is creating the virtual disk in the H730 controller BIOS before the OS sees the volume.

What maintenance will the 2 x 750W redundant power supplies need later?

They are hot-swap modules; if one fails, pull the faulty unit and insert a replacement while the server stays running — no tools required.

Which limit appears first when the single E5-2650 v3 runs sustained workloads?

The 16 GB installed DDR4 across 24 DIMM slots fills quickly; memory capacity becomes the bottleneck before CPU or drive throughput.

同類商品

顧客也比較過

同一分類,同一套結帳流程 — 支援八種加密貨幣,匯率鎖定 30 分鐘。