我們接受加密貨幣付款 — 讓您持有的幣種也能買到真正的硬體設備。以加密貨幣付款,直接購入真正的硬體設備。 全球訂單滿 US$399,即享免費保險運送。簡約外箱,不印任何品牌標誌,從德國出貨。訂單滿 US$399,即享免費保險運送。 結帳一開始,您的匯率即鎖定 30 分鐘。匯率鎖定 30 分鐘。 每件商品皆原廠密封、序號經過核對,並享有 24 個月保固。原廠密封,保固 24 個月。

追蹤清單 登入

Fans

Fans 109S072UL 120×120×38 mm 220 V 18/16 W case fan

SKU CH-GDM9-TSJW3 MPN 109S072UL

Original Japan 120 × 120 × 38 mm 220 V AC case fan delivering 18 W at 50 Hz and 16 W at 60 Hz

  • Aluminium frame resists corrosion in industrial environments
  • 120 mm square footprint fits standard mounting holes
  • 38 mm depth suits compact chassis layouts
  • Dual-frequency 50/60 Hz motor runs on global mains supplies
  • Low 16/18 W draw keeps operating costs down

220 V AC case fan for industrial chassis

This 120 mm square aluminium-frame fan runs directly from 220 V mains at 50 or 60 Hz. It suits equipment builders and maintenance engineers who need a drop-in replacement for legacy server, medical or rail-vehicle enclosures. The unit is supplied new from original SANYO production. No external DC supply or PWM controller is required.

Thermal and acoustic profile in service

Power draw is 18 W at 50 Hz and 16 W at 60 Hz, with current of 0.11 A and 0.09 A respectively. The AC motor spins at line frequency, so airflow and noise stay constant regardless of system load. There is no speed curve to tune and no low-speed stall point to manage.

Aluminium frame and lead-wire mounting

The 38 mm deep frame uses corner mounting holes compatible with standard 120 mm fan grilles. Two flying leads exit the housing for direct connection to mains terminal blocks. The metal construction resists vibration in rack-mount and vehicle applications where plastic frames can fatigue.

商品特色

  • Aluminium frame resists corrosion in industrial environments
  • 120 mm square footprint fits standard mounting holes
  • 38 mm depth suits compact chassis layouts
  • Dual-frequency 50/60 Hz motor runs on global mains supplies
  • Low 16/18 W draw keeps operating costs down

商品規格

本商品目前尚未公佈規格。

商品問答

How do I wire the 220 V AC fan into my case, and which step is often missed?

Connect live and neutral to the two supply leads; the step often missed is earthing the aluminium frame through the mounting screws.

What maintenance will the 109S072UL need over time?

Periodically vacuum dust from the blades and frame; the sleeve bearing is not user-serviceable, so plan to replace the unit when noise or vibration increases.

What limit appears first during continuous 220 V operation?

The motor draws 0.11 A at 50 Hz and 0.09 A at 60 Hz; sustained running at the higher 18 W / 0.11 A rating is the thermal limit reached first.