ASUS Vivo AiO V241EA-DB003 all-in-one PC 23.8" Intel Pentium Gold 7505 8GB DDR4 512GB
- Windows 10 Home 🙋♀…
- Intel Pentium Gold…
HPE
A 1U rack server with dual 12-core Xeon 4410y processors, 1TB DDR5 memory and 61.44TB SAS SSD storage, Windows Server 2025 Standard licence included
The HPE ProLiant DL360 Gen11 is a 1U rack server built for hybrid environments that need dense compute and fast storage. It ships with dual Xeon Silver 4410y processors, each delivering 12 cores at 2.00 GHz with a 3.90 GHz turbo ceiling. Sixteen 64 GB DDR5-4800 ECC buffered modules provide 1 TB of memory capacity. Eight 7.68 TB enterprise SAS 12Gb/s SSDs yield 61.44 TB of raw flash storage. A Windows Server 2025 Standard licence for 16 cores is included.
Dual redundant power supplies keep the platform running through a single-module failure. The embedded four-port 1 GbE OCP 3.0 adapter handles baseline connectivity without extra cards. HPE iLO 6 with Intelligent Provisioning gives administrators full remote control over power, boot media and hardware health from any browser. The MR408i-o Gen11 storage controller uses four gigabytes of cache and eight PCIe lanes to sustain SSD throughput under sustained write loads.
The bundled rail kit lets the 1U chassis slide into standard racks without extra hardware. Memory modules and SSDs ship separately and must be installed before first boot, so plan time for population and RAID configuration. PCIe Gen5 slots remain available for additional network or accelerator cards if the workload grows. The OCP 3.0 form factor keeps the front mezzanine free for future storage controller upgrades.
| Type | Rack |
|---|---|
| CPU Type | Intel Xeon |
| MAX Processors | 2 |
| Memory Type | DDR5 |
| Max Memory Capacity | 1TB |
Power down the 1U chassis, open the top cover, populate all 16 DIMM slots with the 64GB DDR5-4800 modules following the socket sequence on the air baffle, then mount each 7.68TB 2.5" SAS SSD into the front drive bays and connect them to the MR408i-o controller.
The redundant power supplies and cooling fans are the primary field-replaceable units; the 8 enterprise SAS SSDs carry a finite write endurance rating, so plan drive swaps once their SMART media-wear indicator approaches the threshold.
The 1U form factor constrains airflow, so sustained all-core turbo on the dual 12-core processors will hit the chassis thermal envelope before the redundant power supplies reach their rated output.