myVolts
myVolts LRS-150F-24 150W 24V 6.5A Power Supply
An enclosed 150 W switching supply delivering 24 V at 6.5 A with universal 85–264 VAC input and 90 % efficiency
- TypeAT
- Delivers 150 W continuous power at 24 V 6.5 A
- Universal 85–264 VAC input handles global mains voltages
- Certified to EN 62368-1, EN 60335-1 and EN 61558-1/-2-16
- Free-air convection cooling with no-load draw below 0.5 W
- Operates from -30 °C to 70 °C at up to 5000 m altitude
Industrial 24V 150W Power Supply
This 24 volt 150 watt enclosed switching supply delivers 6.5 amps for industrial automation, mechanical equipment and electronic instruments. It accepts a universal 85 to 264 volt AC input and operates from minus 30 to 70 degrees Celsius. The metal housing provides convection cooling without a fan. The unit measures 30 millimetres high in a 1U low-profile form factor.
Protections and Compliance
Built-in safeguards include short circuit, overload, over voltage and over temperature protection. The supply meets IEC and EN 60335-1, EN 61558-1 and 2-16 for household appliances, plus EN 62368-1 and UL 62368-1 for industrial equipment. An LED indicator shows power-on status and no-load consumption stays below 0.5 watts.
Installation Notes
Mount the unit in a control cabinet or enclosure with adequate airflow for convection cooling. Verify the AC input wiring matches local mains voltage before energising. The screw terminals accept standard ferrules or stripped wire for secure connections. Ensure the operating altitude does not exceed 5000 metres and vibration remains within the 5G test rating.
商品特色
- Delivers 150 W continuous power at 24 V 6.5 A
- Universal 85–264 VAC input handles global mains voltages
- Certified to EN 62368-1, EN 60335-1 and EN 61558-1/-2-16
- Free-air convection cooling with no-load draw below 0.5 W
- Operates from -30 °C to 70 °C at up to 5000 m altitude
商品規格
| Type | AT |
|---|
商品問答
Will the internal fan need replacing after continuous 24/7 operation?
The LRS-150F-24 uses free-air convection cooling with no internal fan, so there is no fan to wear out or replace.
At what output current does the over-load protection engage on the 24 V rail?
The 24 V rail is rated for 6.5 A continuous; the built-in overload protection triggers above that level to protect the supply.
How hot does the metal enclosure get when the unit runs at full load all day?
The enclosure is designed to operate up to 70 °C ambient; at full 150 W load its 90 % efficiency keeps surface temperature within that limit.
同類商品
顧客也比較過
同一分類,同一套結帳流程 — 支援八種加密貨幣,匯率鎖定 30 分鐘。