我們接受加密貨幣付款 — 讓您持有的幣種也能買到真正的硬體設備。以加密貨幣付款,直接購入真正的硬體設備。 全球訂單滿 US$399,即享免費保險運送。簡約外箱,不印任何品牌標誌,從德國出貨。訂單滿 US$399,即享免費保險運送。 結帳一開始,您的匯率即鎖定 30 分鐘。匯率鎖定 30 分鐘。 每件商品皆原廠密封、序號經過核對,並享有 24 個月保固。原廠密封,保固 24 個月。

追蹤清單 登入

myVolts

myVolts MDR-40-12 40W 12V 3.33A DIN rail power supply

SKU CH-32KR-7H7ET

DIN-rail switching supply delivers 12 V at 3.33 A from 100-240 VAC input with short-circuit, overload, over-voltage and over-temperature protection

  • TypeAT
  • Universal 100-240VAC input works worldwide
  • 12V 3.33A single output delivers stable 40W power
  • Multi-protection guards against short circuit overload overvoltage overheat
  • ABS housing resists impact scratches and meets UL CUL TUV CB CE
  • Mounts on TS35 DIN rail 7.5mm or 15mm profile

Industrial DIN-rail power supply

The myVolts MDR-40-12 is a 40W single-output switching supply that delivers 12V at 3.33A from a 100-240VAC input. It mounts on ultra-thin TS35/7.5 or 15 DIN rails and is housed in ABS material for impact and scratch resistance. The unit suits control panels, automation cabinets and similar industrial installations.

Replaces bulkier linear units

This supply upgrades from larger linear transformers where cabinet space is limited and universal AC input is required. The jump is worth it when a compact, protected DC source must fit on a standard 35mm rail without forced-air cooling.

40W continuous headroom

The 12V 3.33A output comfortably runs PLCs, sensors, relays and small HMIs within its rated 40W. It runs out when the load approaches the 3.33A limit or when inrush currents exceed the built-in overload protection threshold.

商品特色

  • Universal 100-240VAC input works worldwide
  • 12V 3.33A single output delivers stable 40W power
  • Multi-protection guards against short circuit overload overvoltage overheat
  • ABS housing resists impact scratches and meets UL CUL TUV CB CE
  • Mounts on TS35 DIN rail 7.5mm or 15mm profile

商品規格

TypeAT

商品問答

Will the MDR-40-12 clip onto a TS35 DIN rail with a 7.5 mm or 15 mm profile?

Yes, the unit is designed for ultra-thin industrial-grade DIN rail TS35/7.5 or 15 and snaps on without tools.

What is the correct wiring sequence when connecting the 100-240 VAC input to the MDR-40-12?

Connect live, neutral and earth to the marked input terminals before switching on; reversing live and neutral is the most common error.

How often should the internal cooling airflow around the ABS housing be checked on the MDR-40-12?

Inspect the ventilation gaps every six months and clear any dust build-up to maintain the overheat protection margin.