TKD-Lambda RFE1600-24/S 24V 67A 1608W rack-mount power supply

SKU CH-3B1P-FRBD8 MPN RFE1600-24/S

Delivers 24 V at 67 A with 1.608 kW output from 85–265 VAC input in a 12.6 in deep rack enclosure

  • Delivers 1608 W from a single 24 V output at 67 A
  • Accepts 85–265 VAC input across 47–63 Hz for global mains
  • 3 kVrms isolation protects connected equipment from transients
  • Managed via Web, SNMP and Telnet for remote monitoring
  • Compact 1.61 in high rack-mount form factor saves space

24 V 67 A single-output rack supply

This 1.608 kW enclosed AC-DC converter delivers 24 V at up to 67 A from a single output. It accepts 85 to 265 VAC at 47 to 63 Hz and provides 3 kVrms isolation. Web, SNMP and Telnet protocols allow remote monitoring in industrial and commercial installations.

Suited for fixed 24 V loads in rack cabinets

The unit fits a 3.35 in wide, 1.61 in high, 12.6 in deep slot and is designed for permanent mounting in standard equipment racks. Builders needing adjustable voltage, multiple outputs or desktop form factors should consider other product lines.

1608 W at 24 V from one output

Maximum continuous power is 1608 W at the fixed 24 V rail, so the load must not exceed 67 A. The wide 85 to 265 VAC input range covers global mains without manual switching.

商品特色

  • Delivers 1608 W from a single 24 V output at 67 A
  • Accepts 85–265 VAC input across 47–63 Hz for global mains
  • 3 kVrms isolation protects connected equipment from transients
  • Managed via Web, SNMP and Telnet for remote monitoring
  • Compact 1.61 in high rack-mount form factor saves space

商品規格

本商品目前尚未公佈規格。

商品問答

At what output current does the 24 V rail hit its 1608 W limit?

The single 24 V output is rated for 67 A, which equals the 1608 W maximum power rating.

How loud or hot does the enclosed 1.61 in high unit get during continuous 1608 W operation?

The enclosed rack-mount design dissipates up to 1608 W within a 1.61 in high chassis; thermal performance depends on rack airflow and ambient temperature.

Which management interface must my network already support to monitor this supply remotely?

Remote monitoring uses Web, SNMP or Telnet protocols over the management interface; your network must allow one of these.