我們接受加密貨幣付款 — 讓您持有的幣種也能買到真正的硬體設備。以加密貨幣付款,直接購入真正的硬體設備。 全球訂單滿 US$399,即享免費保險運送。簡約外箱,不印任何品牌標誌,從德國出貨。訂單滿 US$399,即享免費保險運送。 結帳一開始,您的匯率即鎖定 30 分鐘。匯率鎖定 30 分鐘。 每件商品皆原廠密封、序號經過核對,並享有 24 個月保固。原廠密封,保固 24 個月。

追蹤清單 登入

APC

APC SMX2200RMLV2U Smart-UPS X 2200VA 1980W 2U Rack/Tower 120V 8 Outlets SmartSlot

SKU CH-FVR9-SV45H MPN SMX2200RMLV2U

Line-interactive 2U rack/tower UPS delivers 2200 VA / 1980 W pure sine-wave output with six 5-15R and two 5-20R outlets, hot-swappable batteries, SmartSlot and USB/serial management

  • International Version120V
  • Input Voltage Range70 - 153V
  • Input Frequency50/60 Hz +/- 3 Hz (auto sensing)
  • Input ConnectionNEMA L5-30P
  • VA Rating2200 VA
  • Watts1980 Watts
  • 2200 VA capacity supports critical servers and network gear
  • 1980 W output delivers full rated power for dense loads
  • Pure sine-wave output protects sensitive electronics during outages
  • Hot-swappable battery enables replacement without powering down equipment
  • 2U rack/tower design fits standard racks or stands on the floor

Smart-UPS X 2200VA for rack or tower use

This line-interactive UPS delivers 2200 VA and 1980 W of sine-wave output for servers, network gear and storage arrays. It accepts 70 V to 153 V input at 50 Hz or 60 Hz and provides eight NEMA outlets, six 5-15R and two 5-20R. The unit ships with mounting brackets, support rails and removable feet for 2U rack or tower installation.

Connects via NEMA L5-30P

The input cord uses a locking NEMA L5-30P plug, so a matching receptacle or PDU is required. One SmartSlot bay accepts an optional management card for network monitoring. Serial and USB cables are included for direct host communication. Hot-swappable battery modules APCRBC117 and APCRBC117J can be replaced without powering down the load.

Typical backup is 25 minutes at half load

Sealed lead-acid batteries recharge in about three hours and are maintenance-free. Transfer time is 4 ms. Surge energy rating is 540 J. The unit weighs 84.60 lb and measures 3.4 in high, 17 in wide and 26.3 in deep. Certifications include UL 1778, UL 1449, CSA, FCC Part 15 Class A and RoHS compliance.

商品特色

  • 2200 VA capacity supports critical servers and network gear
  • 1980 W output delivers full rated power for dense loads
  • Pure sine-wave output protects sensitive electronics during outages
  • Hot-swappable battery enables replacement without powering down equipment
  • 2U rack/tower design fits standard racks or stands on the floor

商品規格

BrandAPC
SeriesSmart-UPS X
ModelSMX2200RMLV2U
International Version120V
Input Voltage Range70 - 153V
Input Frequency50/60 Hz +/- 3 Hz (auto sensing)
Input ConnectionNEMA L5-30P
VA Rating2200 VA
Watts1980 Watts
Output Voltage120V
Output Frequency50/60Hz +/- 3 Hz
Outlets8
Outlet Type(6) NEMA 5-15R
(2) NEMA 5-20R
Battery TypeSealed Lead Acid
Battery Recharge Time3 hour(s)
Battery ReplaceableAPCRBC117, APCRBC117J
AlarmsAlarm when on battery: distinctive low battery alarm: configurable delays
Interface PortSmart-Slot
Rackmountable2U
Surge Energy Rating540 Joules
FeaturesReceptacles: 2 x NEMA 5-20R,6 x NEMA 5-15RSwitching Time: 4 msLoad Capacity (VA): 2200 VALoad Capacity (Watt): 1980 WInput Voltage: 110 V ACOutput Voltage: 120 V ACBackup/Run Time (Full Load): 10 MinuteMaximum Battery Recharge Time: 3 HourHeight: 3.4" (85.3 mm)Width: 17" (431.8 mm)Depth: 26.3" (667 mm)Rack Height: 2UForm Factor: Rack-mountableWeight (Approximate): 38.37 kgPackage Contents: Smart-UPS X SMX2200RMLV2U 2200 VA Rack-mountable UPSCD with SoftwareDocumentation CDInstallation GuideRack Mounting BracketsRack Mounting HardwareRack Mounting Support RailsRemovable Support FeetSm
Dimensions3.35" x 16.97" x 26.26" (H x W x D)
Weight84.77 lbs.
Package Contents87749N
出貨重量45.36 kg
包裝尺寸876 × 597 × 241 mm

其他版本

同系列還有 5 款

同系列產品,記憶體、散熱器或時脈不同 — 下單前請先比較。

商品問答

How long will the SMX2200RMLV2U run my full 1980 W load on battery?

At full 1980 W load the unit provides 10 minutes of runtime before shutdown.

How much heat and noise does the UPS add when it runs continuously in a rack?

The 2U chassis draws 84.6 lb and uses internal fans that activate under load; typical rack airflow handles the heat.

Which input plug must my circuit provide for the NEMA L5-30P cord?

A 120 V, 30 A NEMA L5-30R receptacle on a dedicated branch circuit is required.

同類商品

顧客也比較過

同一分類,同一套結帳流程 — 支援八種加密貨幣,匯率鎖定 30 分鐘。