CyberPower OR1500PFCLCD UPS 1500 VA 1050 W 8 Outlets
- 120V
- 78 - 142 V
CyberPower
Line-interactive UPS with pure sine-wave output, 1000 VA / 700 W, eight NEMA 5-15R outlets, DB-9 and USB ports, and user-replaceable batteries
Options OR1000PFCLCD
The CyberPower OR1000PFCLCD delivers 1000 VA and 700 W of pure sinewave output from a mini-tower chassis. It targets department servers, workgroup servers, network devices, telecom appliances and high-end audio/video equipment that require PFC-compatible power. Automatic Voltage Regulation corrects brownouts and over-voltages without draining the battery. Eight NEMA 5-15R outlets provide protected connections for multiple devices.
The unit accepts an input range of 78 to 142 V at 50 or 60 Hz and maintains output at 120 V ±5% with frequency held to ±1%. AVR handles minor fluctuations on utility power so the sealed lead-acid battery stays charged for genuine outages. Surge diversion meets UL1778 and FCC Class B limits. The replaceable battery cartridge RB1290X2A recharges in eight hours after a discharge event.
At 50% load the battery sustains connected gear for 17.5 minutes; at 100% load it lasts 9.5 minutes. This window is the decisive figure for planning graceful shutdowns via the included PowerPanel Business Edition software over USB or DB-9. Buyers who need longer autonomy for the same load should consider a higher-capacity model. The 120 V input connection uses a standard NEMA 5-15P plug.
| Brand | CyberPower |
|---|---|
| Series | PFC Sinewave Series |
| Model | OR1000PFCLCD |
| International Version | 120V |
| Input Voltage Range | 78 - 142 V |
| Input Frequency | 50/60 Hz +/- 3 Hz |
| Input Connection | NEMA 5-15P |
| VA Rating | 1000 VA |
| Watts | 700 Watts |
| Output Voltage | 120V +/- 5% |
| Output Frequency | 50/60 Hz +/- 1% |
| Outlets | 8 |
| Outlet Type | NEMA 5-15R |
| Battery Type | Sealed Lead Acid |
| Battery Run Time | At Half Load (min): 17.5 At Full Load (min): 9.5 |
| Battery Recharge Time | 8 Hour(s) |
| Battery Replaceable | RB1290X2A |
| Interface Port | DB-9, USB |
| Management Software | PowerPanel Business Edition |
| Approvals | UL1778 4th, cUL 107.3-05, FCC/DoC Class B |
| Surge Energy Rating | 1030 Joules |
| Protection | Internal circuitry limiting / circuit breaker |
| Features | 1000VA / 700W Sine Wave UPS Line-Interactive Topology AVR & GreenPower UPS Mini-Tower Form Factor Multifunction LCD Panel 8 Outlets USB and Serial Communication Ports EMI/RFI Filters PowerPanel Business Edition |
| Dimensions | 6.40" x 5.40" x 13.80" (H x W x D) |
| Weight | 24.7 lbs. |
| VA | No |
| Watt | N/A |
| Options | OR1000PFCLCD |
| 出貨重量 | 12.50 kg |
| 包裝尺寸 | 478 × 284 × 267 mm |
其他版本
同系列產品,記憶體、散熱器或時脈不同 — 下單前請先比較。
Plug the NEMA 5-15P input into a 120 V wall outlet, connect equipment to the eight NEMA 5-15R outlets, then attach the USB or DB-9 cable and install PowerPanel Business Edition so the UPS can trigger graceful shutdowns.
The sealed lead-acid battery is user-replaceable with part RB1290X2A; after extended use it will need swapping and the unit requires an 8-hour recharge cycle after each deep discharge.
At full 700 W load the battery lasts 9.5 minutes, so runtime is the first constraint; at half load it extends to 17.5 minutes before shutdown is forced.