HP

HP ProLiant DL160 Gen9 1U rack server E5-2603 v3 6C 1.6GHz 8GB DDR4 B140i 8 SFF

SKU CH-SCXM-NYR57

1U rack server with eight 2.5-inch bays, single Xeon E5-2603 v3 six-core 1.6GHz CPU, 8GB DDR4, B140i SATA RAID and 550W power supply

  • TypeRack
  • Rack Height1U
  • Redundant Hot-swap PowerYes
  • CPU TypeIntel Xeon E5 v3
  • MAX Processors2
  • ChipsetIntel C610

Installed Memory Size 8GB

HDD None

  • Six-core Xeon E5-2603 v3 at 1.6 GHz handles multi-threaded workloads
  • 8 GB DDR4 ECC registered memory protects data integrity
  • Eight 2.5" SFF drive bays provide dense local storage
  • B140i software RAID supports RAID 0, 1, 5 for SATA redundancy
  • Redundant hot-swap 550 W power supply keeps the server running

1U Rack Server with Xeon E5-2603 v3

The HP ProLiant DL160 Gen9 is a 1U rack server built for general-purpose workloads. It ships with a single Intel Xeon E5-2603 v3 six-core processor at 1.6 GHz and 8 GB of DDR4 memory. The chassis provides eight 2.5-inch SFF drive bays and redundant hot-swap power supplies.

Suited for SATA storage and moderate compute

This configuration suits buyers who need a dense 1U platform with SATA-only software RAID levels 0, 1 and 5 via the B140i controller. Builders who require hardware RAID with battery-backed cache, more than eight internal drives, or support for drive interfaces beyond SATA should look at other platforms.

Eight SFF bays and B140i SATA RAID

The decisive specification is the combination of eight SFF bays and the B140i controller limited to SATA RAID 0, 1 and 5. If your deployment needs more bays, SAS connectivity or dedicated RAID hardware, this server will not meet the requirement.

商品特色

  • Six-core Xeon E5-2603 v3 at 1.6 GHz handles multi-threaded workloads
  • 8 GB DDR4 ECC registered memory protects data integrity
  • Eight 2.5" SFF drive bays provide dense local storage
  • B140i software RAID supports RAID 0, 1, 5 for SATA redundancy
  • Redundant hot-swap 550 W power supply keeps the server running

商品規格

BrandHP
SeriesProLiant
ModelProliant DL160 G9
TypeRack
Rack Height1U
Redundant Hot-swap PowerYes
CPU TypeIntel Xeon E5 v3
MAX Processors2
ChipsetIntel C610
Installed Memory Size8GB
Memory TypeDDR4
Max Memory Capacity8GB
Memory Features16 DIMM slots, 8 per processor. (4GB/8GB/16GB/32GB/64GB DDR4 up to 2400MT/s ECC Registered, actual memory speed dependent on the processor capability).
Number of Memory Slots16
Storage ControllerB140i Software RAID
SSD (Installed)No
Raid Level0,1,5
Media DrivesNone
GPU TypeMatrox G200
Video Memory16MB
Remote ManagementiLO Management (standard).
LAN Ports2 x Ports
Expansion SlotsCPU1 PCIe Riser 1: 2 PCIe 3.0 Slots (1 & 2) available: 1x Full-Height Half Length, 1x Low Profile slot. Optional kit available to install Flexible LOM in slot 1. CPU 2 Riser (Optional): PCIe 3.0 slot 3 - Full-Height Half Height (Secondary PCIe Riser and dual CPU required).
Operating SystemNo
Compatible/Certified OSMicrosoft Windows Small Business Server 2011/2008, Microsoft Windows Server 2008 R2 SP1/SP2, Microsoft Windows HPC Server 2008 R2, Novell SUSE Linux Enterprise Server, Red Hat Enterprise Linux, Oracle Solaris
Weight63.0000LBS

其他版本

同系列還有 5 款

同系列產品,記憶體、散熱器或時脈不同 — 下單前請先比較。

商品問答

How many 2.5-inch drive bays does the 1U chassis provide for mounting drives?

The chassis includes eight SFF bays that accept 2.5-inch drives. Two drive trays with screws are supplied; the remaining bays are empty and ready for additional trays.

What is the correct order for installing the second processor and its matching memory modules?

Install the second processor first, then populate its eight associated DIMM slots. The system will not recognise memory assigned to a missing processor, so the CPU must be seated before adding those modules.

When should the 550W hot-swap power supply be replaced to maintain redundancy?

Replace the unit as soon as the front-panel health LED shows amber or the iLO log reports a power-supply fault. Hot-swap capability lets you swap the module without powering down the server.