We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Vertiv

Vertiv AL6A0NHUGNNXLKB UPS 5kVA/4.5kW 208/120V LLNG 8min runtime

SKU CH-WRE9-1PT39 MPN AL6A0NHUGNNXLKB

Double-conversion online UPS delivers 5 kVA/4.5 kW with lithium-ion batteries giving eight minutes at full load and hot-swappable modules for maintenance without downtime

  • International Version208V
  • Input Voltage Range200/100, 208/120, 220/110, 230/115, 240/120 VAC
  • Input Frequency40 Hz to 70 Hz auto-sensing
  • Input Connection4-Wire (L-L-N-G)
  • VA Rating5kVA
  • Watts4.5kW
  • Double-conversion online topology protects critical loads with clean power
  • Hot-swappable power, battery and control modules enable maintenance without load interruption
  • Lithium-ion battery delivers 8 minutes at full load and 17 minutes at half load
  • Wide input range from 200/100 to 240/120 VAC with 40 Hz to 70 Hz auto-sensing
  • Rack/tower form factor fits 38" x 17" x 34" footprint at 361 lbs

5kVA double-conversion UPS for critical loads

The Vertiv Liebert AL6A0NHUGNNXLKB is a 5kVA, 4.5kW online UPS that accepts 200/100 through 240/120 VAC input and delivers the same split-phase voltages to connected equipment. It uses lithium-ion batteries and hot-swappable power, battery and control modules so maintenance can occur without interrupting the load.

Runtime at full and half load

At full rated load the unit provides 8 minutes of battery runtime, extending to 17 minutes when the load is reduced by half. The double-conversion topology continuously regenerates clean output power, isolating attached devices from input frequency variations across the 40 Hz to 70 Hz auto-sensing range.

Operating envelope and acoustic profile

The UPS operates between 32°F and 104°F in humidity up to 95 percent non-condensing, and weighs 361 lbs in a 38" x 17" x 34" rack or tower chassis. Output frequency defaults to 60 Hz with user-configurable 50/60 Hz selection for regional compatibility.

Highlights

  • Double-conversion online topology protects critical loads with clean power
  • Hot-swappable power, battery and control modules enable maintenance without load interruption
  • Lithium-ion battery delivers 8 minutes at full load and 17 minutes at half load
  • Wide input range from 200/100 to 240/120 VAC with 40 Hz to 70 Hz auto-sensing
  • Rack/tower form factor fits 38" x 17" x 34" footprint at 361 lbs

Specifications

BrandVertiv
SeriesLiebert
ModelAL6A0NHUGNNXLKB
International Version208V
Input Voltage Range200/100, 208/120, 220/110, 230/115, 240/120 VAC
Input Frequency40 Hz to 70 Hz auto-sensing
Input Connection4-Wire (L-L-N-G)
VA Rating5kVA
Watts4.5kW
Output Voltage200/100, 208/120, 220/110, 230/115, 240/120 VAC
Output Frequency60Hz default; 50/60Hz user-configurable
Battery TypeLithium Ion
Battery Run TimeFull Load: 8 mins.
Half Load: 17 mins.
TemperatureOperating temperature: 32°F - 104°F (0°C - 40°C)
Humidity0 - 95%, non-condensing
Dimensions38" x 17" x 34"
Weight361 lbs.
Shipping weight163.75 kg
Package size965 × 965 × 432 mm

Other versions of this model

5 more in the same range

Same family, different memory, cooler or clock — compare before you commit.

Questions about this item

How much heat does the 5kVA Liebert UPS add to a rack row running 24/7?

The unit operates between 32°F and 104°F with 0–95% non-condensing humidity; its double-conversion design and lithium-ion batteries run efficiently at 4.5kW full load, so plan cooling for the rated 361 lb chassis in a 38" x 17" x 34" footprint.

What input wiring must the site already provide for the 4-wire L-L-N-G connection?

A 208/120 VAC three-phase service with neutral and ground, capable of 40–70 Hz, is required; the UPS accepts 200/100, 208/120, 220/110, 230/115 or 240/120 VAC ranges automatically.

Will my existing 208/120 VAC PDUs and servers work with the configurable 50/60 Hz output?

Yes — output voltage matches 200/100 through 240/120 VAC and frequency defaults to 60 Hz with user-selectable 50 Hz, so current 208/120 VAC loads connect without adapters.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.